background image

FCS 

PDS II 

Product Manual

!"#$%&'()*+)%,-./%0'*1.%2$$/%3456'1%7+..)/%7,%"8#"9%%%%%%%%%%%%

"!#:#;<:88#"%=%>'(1*6?@A(:'(B6.1%%%%%%%%%%%

!"#$%#&'(#"")(*+*'),*-%#,

!"#$%#&'(#"")(*+*'),*-%#,

Summary of Contents for FCS PDS II

Page 1: ...FCS PDS II Product Manual 0 1 2 3456 1 7 7 8 9 88 1 6 A B6 1...

Page 2: ...bing as needed Please connect power directly to a wall socket Avoid using an extension cord If power line or plug have wear or other damage please unplug it by holding the plug not the line If the fol...

Page 3: ...rface fracture 4 Filling Volume Reference Parameter Media is Water 14 PDS II Technical Specifications 15 Product Size Chart 16 Main Functions and Features of PDS II 17 External Control Interface Instr...

Page 4: ...models of each filling unit can be the same or different In logic working mode many filling units are operated according to the preset logical relation The tubing size and pump models of each filling...

Page 5: ...t C Controller Product Composition PDSII consists of one controller and many independent filling units adding or deleting filling units as needed You can also set the validity of each filling unit as...

Page 6: ...t 2 Each controller can control 8 filling units max A B C Back side of filling unit Interface Specification A Power switch B Power socket C Interface connecting the controller G Interface Specificatio...

Page 7: ...ps Date and Time Check the parameter s Commonly used logic operation mode Run independentl y commonly used mode The flow calibration PDS II controller operation interface introduction 1 Boot interface...

Page 8: ...y change the flow rate speed and direction Other parameters can t be modified c If the unit is not the effective unit it will highlight errors when clicking the bottle C Choose Looping units Click to...

Page 9: ...button to enter the communication setup interface 4 Loop unit selecting interface Select the unit Please choose to view the unit 1 2 3 4 6 7 8 5 ESC In the main interface you can click the FCS logo t...

Page 10: ...f the unit here When finished you can click the OK button to go back to main interface If a unit is in operation the current working unit can t be modified Please note Selecting effective unit is the...

Page 11: ...ault setting C Transferring working mode Parameter settings This area is for setting the transferring parameters Click the sign to select this mode and set the start delay flow rate and speed of this...

Page 12: ...the target volume is the calculation result of current flow rate and working time It is not modified The default working time is 60s You can click it to modify Calibration process before working A En...

Page 13: ...ing volume returns to 0 8 Logic working mode checking interface Logic working mode checking interface table In the running state of the allocation mode click on the running bottle at the main interfac...

Page 14: ...the select all button selects all units If the running unit is in transmission mode then you can choose the unit but you cannot change the direction If in allocation mode or logic mode the unit is eff...

Page 15: ...e system settings interface Add and subtract page button If you have more than one common mode click on this button to view the previous page or the next page of the commonly used mode Save mode butto...

Page 16: ...achine Input the peristaltic pump address number 1 32 for selecting a communication enable to on Now the pump can communicate with the PC receiving a PC control signal Note After the setting is comple...

Page 17: ...nd time and display in the upper right corner of the main interface Click set date button This pops up the digital keyboard Set the year range for 1970 2099 After setting click OK to enter the month t...

Page 18: ...0 5 17 24 30 1 2 0 8 17 24 50 2 0 5 18 80 2 5 0 5 18 100 3 0 5 DZ25 3L 35 150 4 0 5 36 200 4 0 5 PDS II Technical Specifications Dispensing volume 0 1 9999ml Prime speed 600rpm Dispensing time range...

Page 19: ...lution 0 01s Relative Wet 80 Dispensing numbers 1 9999 0means unlimited Controller Dimension L W H 240 185 85 mm Speed range 0 1 600rpm Controller weight 2 5Kg Back suction angle 0 360 IP rate IP31 Pr...

Page 20: ...ensure the filling accuracy Online micro adjusting function Helps you adjust the liquid volume to a certain filling unit in order to prevent filling error caused by fatigue and the elasticity of the h...

Page 21: ...g but also can fill liquid in the tubing 304 stainless steel housing resists corrosion no rust conforms to GMP sanitary requests External control interface instruction of the control unit The green te...

Page 22: ...signal input F R S All start and stop signals of the independent operation unit Communication interface TXD RXD GND RS232 communication interface The communication settings interface to select RS232...

Page 23: ...ear of warranty does not include tubing Warranty does not cover the improper operation of this equipment PDS II Flow Controller Systems 2950 Buskirk Ave Suite 300 Walnut Creek CA 94597 Tel 925 516 445...

Reviews: