Specifications • Safety 

2

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Descripti on

This Submersible Sump Pump is designed for 

home sumps. The permanent split capacitor 

motor is oil filled, sealed for cooler running, 

and has automatic-reset thermal protection. 

Ball bearings on the motor shaft never need 

lubrication. The power cord is a 3-wire, 

grounding-type cord.

Specifications

Power supply ...................... 115V, 60 HZ., 15 Amp Circuit
Liquid Temp. Range ......................... 32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ............15 Amps
Discharge: ............................................1-1/2” Female NPT

This pump is designed for use in a residential 

sump only. Pump water only with this pump.
NOTICE : This unit is not designed as a waterfall 

or fountain pump, or for applications involving 

salt water or brine! Use with waterfalls, 

fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming 

pool drainer.
NOTICE : Read this Owner’s Manual for 

installation, operation, and safety information.

General Safety Information

Your automatic sump pump should give years 

of trouble-free service when correctly installed, 

maintained, and used. However, interruption 

of power to the pump, dirt/debris in the sump, 

flooding that exceeds the pump’s capacity, 

electrical or mechanical failure in the pump, 

etc., may prevent normal pump operation. To 

help prevent damage from flooding, purchase 

a secondary AC sump pump, a DC backup 

sump pump, and/or a high water alarm. See 

Troubleshooting in this manual for information 

about common sump pump problems and 

remedies. For more information,call Flotec 

customer service at 1-800-365-6832 or visit our 

website at FlotecWater.com.

Hazardous voltage. To reduce the risk 

of hazardous or fatal electrical shock, follow 

instructions A through D, below:
A.  This pump has an approved 3-conductor 

power cord with 3-prong, grounding-type plug. 

Connect the pump only to a properly grounded, 

3-prong outlet. If the sump pump circuit has 

a 2-prong outlet, replace it with a grounded 

3-prong outlet installed according to code.

B.  Unplug the pump before handling or servicing 

it. If your basement floor is wet, turn off all 

power before walking on it. If the shut-off box 

is in the basement, call your electric company 

or hydro authority to shut off service to the 

house, or call your local fire department 

for instructions. After turning off the power, 

remove the pump for service.

C.  Protect the electrical cords from sharp objects, 

hot surfaces, oil, and chemicals. Avoid kinking 

the cords. Replace damaged or worn cords.

D.  Do not lift the pump by the power cord.

 Fire hazard. Plastic pipe glue 

is extremely flammable. Follow the glue 

manufacturer’s instructions when assembling 

glued plastic pipe.

 Burn hazard. Modern motors may run 

hot. Allow 20 minutes to cool before handling.
1.  Know the pump application, limitations, and 

potential hazards.

2.  Do not use this pump in water with 

fish present.

3.  Drain the system completely before 

servicing it.

4.  To prevent a flexible discharge line from 

whipping, which could cause injury or 

damage, fasten it down before starting 

the pump.

5.  Before each use, check any hoses in the system 

for weakness or wear. Make certain that all 

connections are tight.

6.  Periodically inspect the sump, the pump, 

and the piping for debris and foreign objects. 

Perform routine cleaning as required.

7.  Personal Safety:

a.  Wear safety glasses at all times when 

working with pumps.

b.  Keep your work area clean, uncluttered 

and properly lighted; put away all unused 

tools and equipment.

c.  Keep visitors at a safe distance from the 

work area.

d.  Make workshop child-proof with padlocks 

and master switches. Remove any 

starter keys.

8.  This pump installation must meet all applicable 

laws, codes, and ordinances.

Tools Required:
Pipe wrench, Strap Wrench, or Slip-Joint Pliers,
Hacksaw,
Screw Driver,
File or Sandpaper
Materials Required:
1-1/2” ABS or PVC Pipe with Cement to match
Threaded Adapter (Pipe to Pump)
Check Valve – Purchase an FP0026-10 (goes in 

the discharge line) or FP0026-6D (goes in the 

pump discharge). If your check valve does not 

have an 1/8” anti-airlock hole, drill one in the 

discharge pipe just below the check valve. Be 

sure to install the check valve so that the flow 

will be away from the pump.

Summary of Contents for FPSC2200A

Page 1: ...erating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 9 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entreti...

Page 2: ...outlet installed according to code B Unplug the pump before handling or servicing it If your basement floor is wet turn off all power before walking on it If the shut off box is in the basement call...

Page 3: ...mp as possible Be sure the hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the discharge pipe near the pump and fasten a short length of rubber hose 1 7 8 48...

Page 4: ...lectrical shock hazard Always ground the pump to a suitable electrical ground such as a grounded water pipe a properly grounded metallic raceway or a ground wire system Do not cut off the round ground...

Page 5: ...harge the pump has probably run dry Shut it off immediately and check the water level Performance GPH At Total Feet Of Lift See Figure 7 Model 5 ft 10 ft 15 ft 20 ft No flow at height shown below Capa...

Page 6: ...ly 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impeller 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 22P 3 Tethered Float Switch Assembly 1 FP18 15BD FP18 15BD Vertical Float Switch Assembly 1 FPS17 66...

Page 7: ...Defective float switch Replace the float switch Restricted discharge obstacle or ice in the piping Unplug the pump remove it from the sump and clean the pump and piping Obstructed float Move the pump...

Page 8: ...wdriver and unscrew the impeller as shown NOTICE The impeller has a left hand thread so it loosens to the right Step 3 Thread the new impeller nto the motor shaft as shown left hand thread tightens to...

Page 9: ...Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump Fo...

Page 10: ...un de mise la terre install e conform ment au code B D brancher la pompe avant de la manipuler ou de l entretenir Si le plancher du sous sol est humide ne pas marcher dessus tant que le courant n aura...

Page 11: ...au dessus de ce trou et aussi pr s que possible de la pompe S assurer que le trou est plus bas que la ligne d eau et que le clapet antiretour 2D Pour r duire le bruit et les vibrations couper le tuya...

Page 12: ...Toujours mettre la pompe la terre sur une terre lectrique ad quate comme un tuyau d eau mis la terre ou un chemin de c bles m tallique ad quatement mis la terre ou un syst me de fils de mise la terre...

Page 13: ...us par le tuyau de refoulement la pompe a probablement fonctionn e sec L arr ter imm diatement et v rifier le niveau d eau Debits Gallons minute la hauteur totale de refoulement Se reporter la Figure...

Page 14: ...es Qt FPSC2200A FPSC2250A FPSC3200A FPSC3250A FPSC4550A 1 Cordon lectrique 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impeller 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 22P 3 Interrupteur flotteur c...

Page 15: ...mpe ne s arr te pas Interrupteur flotteur d fectueux Le remplacer Refoulement obstru obstruction ou pr sence deglace dans les tuyaux D brancher la pompe la sortir du puisard puis la nettoyer ainsi que...

Page 16: ...seur comme illustr AVIS Le filetage de l impulseur gauche il faut donc le tourner droite pour le d visser tape 3 Visser l impulseur neuf sur l arbre d moteur comme il est illustr filetage gauche il fa...

Page 17: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Page 18: ...antes de manipularla o realizar trabajos de reparaci n o mantenimiento Si el piso de su s tano est mojado desconecte la corriente el ctrica antes de caminar sobre el mismo Si la caja de desconexi n es...

Page 19: ...este orificio pero mant ngalo tan cerca de la bomba como sea posible Verifique que el orificio se encuentre debajo de la l nea de agua y por debajo de la v lvula de retenci n 2D Para reducir el ruido...

Page 20: ...medio de una masa el ctrica adecuada como una tuber a de agua conectada a tierra una canalizaci n met lica debidamente conectada a tierra o un sistema de cable a tierra No corte la punta redonda de co...

Page 21: ...a est seca Ap guela inmediatamente y verifique el nivel del agua Desempe o GPH al total de altura de levante en pies Consultar la Figura 7 Modelo 5 pi 10 pi 15 pi 20 pi No hay flujo a la altura indica...

Page 22: ...FPSC4550A 1 Unidad del cord n el ctrico 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impulsor 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 22P 3 Unidad del interruptor de flotador anclado 1 FP18 15BD FP...

Page 23: ...e el interruptor de flotador La bomba no se apaga Interruptor de flotador defectuoso Reemplace el interruptor de flotador Descarga restringida obst culoo hielo en la tuber a Desenchufe la bomba s quel...

Page 24: ...stornillador y destornille el impulsor seg n se ilustra AVISO El impulsor tiene una rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del motor seg n...

Page 25: ...ienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si...

Page 26: ......