Flotec FPSC2200A-10 Owner'S Manual Download Page 2

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. The permanent split capacitor motor is oil filled,
sealed for cooler running, and has automatic-reset ther-
mal protection. Ball bearings on the motor shaft never
need lubrication. The power cord is a 3-wire, grounding-
type cord. 

SPECIFICATIONS

Power supply ....................115V, 60 HZ., 15 Amp Circuit
Liquid Temp. Range......................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) .........15 Amps
Discharge:............................................1-1/2" Female NPT
This pump is designed for use in a residential sump
only. Pump water only with this pump.

NOTICE:

This unit is not designed as a waterfall or foun-

tain pump, or for applications involving salt water or
brine! Use with waterfalls, fountains, salt water or brine
will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

NOTICE: Read this Owner’s Manual for installation,
operation, and safety information. 

GENERAL SAFETY INFORMATION

Your automatic sump pump should give years of
trouble-free service when correctly installed, main-
tained, and used. However, interruption of power to
the pump, dirt/debris in the sump, flooding that
exceeds the pump’s capacity, electrical or mechanical
failure in the pump, etc., may prevent normal pump
operation. To help prevent damage from flooding,
purchase a secondary AC sump pump, a DC backup
sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for informa-
tion about common sump pump problems and reme-
dies. For more information,call Flotec customer 
service at 1-800-365-6832 or visit our website at
www.flotecwater.com.

Hazardous voltage. To reduce the risk of

hazardous or fatal electrical shock, follow instructions
A through D, below:
A. This pump has an approved 3-conductor power

cord with 3-prong, grounding-type plug. Connect
the pump only to a properly grounded, 3-prong
outlet. If the sump pump circuit has a 2-prong out-
let, replace it with a grounded 3-prong outlet
installed according to code.

B. Unplug the pump before handling or servicing it. 

If your basement floor is wet, turn off all power
before walking on it. If the shut-off box is in the
basement, call your electric company or hydro
authority to shut off service to the house, or call
your local fire department for instructions. 

After

turning off the power, remove the pump for 
service.

C. Protect the electrical cords from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking the
cords. Replace damaged or worn cords.

D. Do not lift the pump by the power cord.

Plastic pipe glue is extremely flammable.

Follow the glue manufacturer’s instructions when
assembling glued plastic pipe.

Burn hazard.

Modern motors may run hot.

Allow 20 minutes to cool before handling. 
1. Know the pump application, limitations, and

potential hazards.

2.

Do not use this pump in water with fish present.

3. Drain the system completely before servicing it.
4. To prevent a flexible discharge line from whip-

ping, which could cause injury or damage, fasten
it down before starting the pump.

5. Before each use, check any hoses in the system

for weakness or wear. Make certain that all con-
nections are tight.

6. Periodically inspect the sump, the pump, and the

piping for debris and foreign objects. Perform
routine cleaning as required. 

7. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep your work area clean, uncluttered and

properly lighted; put away all unused tools and
equipment.

c. Keep visitors at a safe distance from the work

area.

d. Make workshop child-proof with padlocks and

master switches. Remove any starter keys.

8. This pump installation must meet all applicable

laws, codes, and ordinances.

Tools Required:

Pipe wrench, Strap Wrench, or Slip-Joint Pliers,
Hacksaw, 
Screw Driver, 
File or Sandpaper

Materials Required:

1-1/2" ABS or PVC Pipe with Cement to match
Threaded Adapter (Pipe to Pump)
Check Valve – Purchase a Flotec FP0026-10 (goes in the
discharge line) or FP0026-6D (goes in the pump dis-
charge).If your check valve does not have a 1/8" anti-air-
lock hole, drill one in the discharge pipe just below the
check valve. Be sure to install the check valve so that the
flow will be 

away from the pump.

Summary of Contents for FPSC2200A-10

Page 1: ...r further operating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 9 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation...

Page 2: ...unded 3 prong outlet installed according to code B Unplug the pump before handling or servicing it If your basement floor is wet turn off all power before walking on it If the shut off box is in the b...

Page 3: ...charge Install the check valve above this hole but keep it as close to the pump as possible Be sure the hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the d...

Page 4: ...hazard Always ground the pump to a suitable electrical ground such as a grounded water pipe a properly ground ed metallic raceway or a ground wire system Do not cut off the round ground pin 6A After y...

Page 5: ...run dry Shut it off immedi ately and check the water level TM E I DuPont De Nemours and Company Corporation Delaware Sump Pit Check Valve Install Vertically Basement Floor Discharge Pipe Lift Figure...

Page 6: ...y FPSC2200A FPSC2250A FPSC3200A FPSC3250A FPSC4550A 1 Power Cord Assembly 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impeller 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 35P 3 Tethered Float Switch As...

Page 7: ...cted discharge Unplug the pump remove it from the sump and clean the obstacle or ice in the piping pump and piping Obstructed float Move the pump in the sump or remove the obstruction Restricted intak...

Page 8: ...ller as shown NOTE The impeller has a left hand thread so it loosens to the right Step 3 Thread the new impeller onto the motor shaft as shown left hand thread tightens to the left Step 4 Re mount the...

Page 9: ...installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials...

Page 10: ...trous dont un de mise la terre install e conform ment au code B D brancher la pompe avant de la manipuler ou de l entretenir Si le plancher du sous sol est humide ne pas marcher dessus tant que le cou...

Page 11: ...lus bas que la ligne d eau et que le clapet antiretour 2D Pour r duire le bruit et les vibrations couper le tuyau de refoulement pr s de la pompe puis poser un petit morceau de tuyau en caoutchouc un...

Page 12: ...re la pompe la terre sur une terre lec trique ad quate comme un tuyau d eau mis la terre ou un chemin de c bles m tallique ad quatement mis la terre ou un syst me de fils de mise la terre Ne jamais co...

Page 13: ...L arr ter imm diatement et v rifier le niveau d eau TM E I DuPont De Nemours and Company Corporation Delaware Sump Pit Check Valve Install Vertically Basement Floor Discharge Pipe Lift Figure 7 REFOUL...

Page 14: ...f des pi ces Qt FPSC2200A FPSC2250A FPSC3200A FPSC3250A FPSC4550A 1 Cordon lectrique 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impulseur 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 35P 3 Interrupteur...

Page 15: ...tir du puisard puis la nettoyer obstruction ou pr sence de ainsi que les tuyaux glace dans les tuyaux Flotteur obstru D placer la pompe dans le puisard ou enlever l obstruction Cr pine d aspiration ob...

Page 16: ...age de l impulseur gauche il faut donc le tourner droite pour le d visser tape 3 Visser l impulseur neuf sur l arbre du moteur comme il est illustr filetage gauche il faut donc le tourner gauche pour...

Page 17: ...enus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pannes de fonctionnement caus es par la corro sion la rouille ou aut...

Page 18: ...la bomba antes de manipularla o realizar trabajos de reparaci n o mantenimiento Si el piso de su s tano est mojado desconecte la corriente el ctrica antes de caminar sobre el mismo Si la caja de desc...

Page 19: ...ucir el ruido y las vibraciones corte la tuber a de descarga cerca de la bomba y fije un tramo de manguera de caucho corto 1 7 8 48 mm de di metro interior por ejemplo una manguera de radiador en la m...

Page 20: ...asa el c trica adecuada como una tuber a de agua conectada a tierra una canalizaci n met lica debidamente conecta da a tierra o un sistema de cable a tierra No corte la punta redonda de conexi n a tie...

Page 21: ...all Vertically Basement Floor Discharge Pipe Lift Figura 7 LEVANTE ALTURA El levante la altura es la distancia vertical efectiva a la cual la bomba levanta el agua Cuanto m s alto sea el levante menor...

Page 22: ...SC3200A FPSC3250A FPSC4550A 1 Unidad del cord n el ctrico 1 PW17 281 PW17 281 PW17 281 PW17 281 PW17 281 2 Impulsor 1 PS5 33P PS5 33P PS5 34P PS5 34P PS5 35P 3 Unidad del interruptor de flotador ancla...

Page 23: ...en la tuber a y la tuber a Flotador obstruido Mueva la bomba en el sumidero o elimine la obstrucci n Malla de admisi n restringida Desenchufe la bomba s quela del sumidero y limpie la malla de admisi...

Page 24: ...mpulsor seg n se ilustra NOTA El impulsor tiene una rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del motor seg n se ilustra rosca izquierda se a...

Page 25: ...otra cosa que no sea su aplicaci n uso o servicio normales incluyendo pero no limitado a fallas operacionales causadas por corrosi n oxidaci n u otros elementos extra os en el sistema o funcionamiento...

Page 26: ...26...

Page 27: ...27...

Page 28: ......

Reviews: