Flotec FPPA-9IL3 Owner'S Manual Download Page 8

Operation

8

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

5. Carefully replace the O-Ring (see Figure 8). Do not

stretch it. Squeeze a little silicone lubricant (included
with your chlorinator) directly onto the O-Ring and
spread it over the O-Ring surface with your finger.

6. Push the control dial completely into the housing and

turn the dial to setting 2 (see Figure 9).

7. Insert the non-lipped end of the snap ring into the

groove in the housing, beginning at the 5:00 o’clock
position. Push it up so that it threads itself around the
control dial (see Figure 10).

8. Guide the snap ring with a small screwdriver (or other

pointed tool) to keep it in the groove in the housing as
it is inserted (see Figure 11).

1

3

4 5 6 7

9

BRO

MINE

P

O

O

L

S

2

TRICHLOR

MIN

MAX

8

L

A

R

G

E

R

S

P

A

S

S

M

A

L

L

E

R

P

O

O

LS

LA

R

G

E

R

P

O

O

L

S

Figure 10

1

3

4 5 6 7

9

BRO

MINE

P

O

O

L

S

2

TRICHLOR

MIN

MAX

8

L

A

R

G

E

R

S

P

A

S

S

M

A

L

L

E

R

P

O

O

LS

LA

R

G

E

R

P

O

O

L

S

Figure 11

3758 0900

Figure 8

Figure 9

Summary of Contents for FPPA-9IL3

Page 1: ...or maintenance assistance Call 1 800 365 6832 2000 PRINTED IN U S A FP346 9 5 00 P O Box 342 Delavan WI 53115 Phone 1 800 365 6832 Fax 1 800 526 3757 E Mail flotec flotecpump com Web Site http www fl...

Page 2: ...These materials are less stable than slow act ing chemicals using them may cause pressure buildup toxic fumes fire or explosion Use only slow dissolving Trichlor Trichloro S Iazinetrione sticks tablet...

Page 3: ...ion at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to FLOTEC as soon as possible after...

Page 4: ...s 6 Isolate the chlorinator by installing a corrosion resistant check valve or a plumbing loop Hartford loop between the chlorinator and the rest of the pool equip ment This will protect other system...

Page 5: ...in pools and most commonly in spas It is more stable and dissolves slower than Trichlor Therefore it requires greater move ment of water over chemical scrubbing action to achieve the same output as T...

Page 6: ...shock manufac turer s recommendations 6 When you have achieved the desired sanitizer level through shocking increase the dial setting by 1 2 increment from the initial setting and begin the process a...

Page 7: ...In the groove to make sure it is in place Finally lubricate O ring with the liquid silicone lubricant provided with your unit LUBRICATION OF CAP O RING If lubrication of O rings becomes necessary use...

Page 8: ...rt the non lipped end of the snap ring into the groove in the housing beginning at the 5 00 o clock position Push it up so that it threads itself around the control dial see Figure 10 8 Guide the snap...

Page 9: ...9940 2 Cap with O Ring Incl Key No 2 1 01 22 9411 3 Cap O RIng 1 01 22 9920 4 Mesh Screen 1 01 22 9660 5 Body 1 6 Pressure Relief Valve 1 01 22 9480 7 Control Dial O Ring Kit 1 01 22 9450 8 Control Di...