Safety

2

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. 

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

The label 

NOTICE

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 

Replace missing or damaged safety labels.

ELECTRICAL SAFETY

Capacitor voltage may be hazardous.

To discharge motor capacitor, hold insulated handle
screwdriver 

BY THE HANDLE

and short capacitor termi-

nals together. Do not touch metal screwdriver blade or
capacitor terminals. If in doubt, consult a qualified 
electrician. 

GENERAL SAFETY

Do not touch an operating motor.

Modern

motors are designed to operate at high temperatures. To
avoid burns when servicing pump, allow it to cool for 20
minutes after shut-down before handling.

Do not allow pump or any system component to freeze.
To do so will void warranty.

Pump water only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

Maximum pressure on shaft seal when pump is not run-
ning must be less than 75 PSI (517kPa) or seal may leak.

Pump body may explode if used as a

booster pump unless relief valve capable of passing full
pump flow at 125 PSI (862 kPa) is installed.

WARNING

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before 
connecting to power 
supply. Disconnect power
before working on pump,
motor or tank.

Wire motor for correct

voltage. See “Electrical”

section of this manual and
motor nameplate.

Ground motor before

connecting to power 

supply.

Meet National Electri-

cal Code, Canadian

Electrical Code, and local
codes for all wiring.

Follow wiring instruc-

tions in this manual

when connecting motor to
power lines.

Summary of Contents for FP5500 Series

Page 1: ...nt Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 8 13 Instalaci n Operaci n Piezas Para mayor informaci n sobre el...

Page 2: ...a qualified electrician GENERAL SAFETY Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes aft...

Page 3: ...red or replaced at FLOTEC s option subject to the terms and conditions set forth below General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace product cover...

Page 4: ...prime following instructions above When used with vertical discharge the vent plug at the top should be loosened to evacuate air which is trapped inside the volute When volute is completely filled wit...

Page 5: ...r 1 2 wrench and turn the volt age selector dial counterclockwise until 115 shows in the dial opening 4 Reinstall the motor cover Hazardous voltage Can shock burn or cause death Disconnect power to mo...

Page 6: ...ls L1 and L2 under motor canopy When replacing motor check wiring diagram on motor nameplate against Figure 3 If the motor wiring diagram does not match either diagram in Figure 3 follow the diagram o...

Page 7: ...9 10 10 10 11 13 12 683 0294 FL Key Part FP5512 08 FP5522 08 FP5532 08 FP5542 08 FP5552 08 No Description Qty 1 2 HP 3 4 HP 1 HP 1 1 2 HP 2 HP 1 Motor 115 230V 60 Cycle Single Phase 1 A100CLL A100DLL...

Page 8: ...ratures lev es Pour ne pas se br ler lorsque l on interviendra sur la pompe la laisser refroidir pendant 20 minutes apr s l avoir arr t e avant de la toucher Ne pas laisser geler la pompe ni aucun au...

Page 9: ...ermes et condi tions stipul s ci dessous Conditions g n rales L Acheteur s engage payer tous les frais de main d uvre et d exp dition n cessaires au remplacement du produit couvert par la garantie Cet...

Page 10: ...l le bouchon d a ration qui se trouve en haut doit tre desserr de fa on chasser l air emprisonn dans la volute Lorsque la volute est compl tement remplie d eau resserrer le bouchon d a ration NE JAMAI...

Page 11: ...on vers la gauche jusqu ce que la valeur 115 soit affich e dans l ouverture du cadran 4 Reposer de nouveau le couvercle du moteur Tension dangereuse Risque de secousses lectriques de br lures voire de...

Page 12: ...nsporteurs de courant sur les bornes L1 et L2 qui se trouvent sous le carter du moteur Lorsque l on remplace le moteur comparer le sch ma de c blage de la plaque signal tique par rapport la Figure 3 S...

Page 13: ...rt e et mal ancr e toute contrainte sur la pompe 1 2 3 4 5 6 8 7 9 10 10 10 11 13 12 683 0294 FL N de D signation FP5512 00 FP5522 00 FP5532 00 FP5542 00 FP5552 00 r f des pi ces Qt 1 2 CV 3 4 CV 1 CV...

Page 14: ...ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del s...

Page 15: ...consumidor original ste ser reparado o reemplazado a opci n de FLOTEC sujeto a los t rminos y a las condiciones indicadas a continuaci n T rminos y Condiciones Generales El comprador debe pagar todos...

Page 16: ...o las instrucciones anteriores Cuando la descarga sea vertical debe aflojarse el tap n de ventilaci n situado en la parte superior para evacuar el aire que est atrapado dentro de la voluta Cuando la v...

Page 17: ...e tensi n hacia la izquierda hasta que se vea 115 en la abertura del cuadrante 4 Vuelva a instalar la cubierta del motor Tensi n peligrosa Puede causar choques quemaduras o muerte Desconecte la corrie...

Page 18: ...os Paso 7 Conecte los conductores que llevan la corriente a los bornes L1 y L2 bajo el techo del motor Cuando cam bie el motor inspeccione el diagrama de cableado en la placa de f brica del motor cont...

Page 19: ...l anclada aliviar los esfuerzos en el conjunto de la bomba 1 2 3 4 5 6 8 7 9 10 10 10 11 13 12 683 0294 FL No de Descripci n FP5512 00 FP5522 00 FP5532 00 FP5542 00 FP5552 00 Ref de las Piezas Cant 1...

Page 20: ...20...

Reviews: