OPERATION

Hazardous voltage. Can shock, burn or

cause death. 

Do not handle a pump or pump motor with

wet hands or when standing on a wet or damp surface, or
in water.

1. Shaft seal depends on water for lubrication. Do not

operate the pump unless it is in water as the seal may
be damaged if allowed to run dry.

2. The motor is equipped with an automatic reset ther-

mal protector. If the temperature in the motor should
rise unduly, the switch will cut off all power before
damage can be done to the motor. When the motor
has cooled sufficiently, the switch will reset automati-
cally and restart the motor. If the protector trips
repeatedly, remove the pump and check it as to the
cause of difficulty. Low voltage, long extension cords,
clogged impeller, very low head or lift, etc., could
cause cycling.

3. The pump will not remove all water. If the pump is

operating and suddenly no water comes out of the
discharge hose, shut off the unit immediately. The
water level is probably very low and the unit has bro-
ken prime.

NOTICE: 

For continuous operation, water must flow

through pump to prevent motor overheating. The
pump is cooled by the water flow through the housing.

4. This pump is designed to pump cold water only.

Pumping heated liquids can overheat the motor and
cause the thermal overload to trip. 

5. Pump can run in water that doesn’t completely cover

the motor housing, but the inlet must be completely
submerged or it will break suction and will not move
any water.

6. Keep the inlet screen clean at all times. If the bottom

surface of the pond or waterfall is dirty, raise the
pump slightly to reduce the amount of debris pulled
into the pump inlet.

7. If you need to reduce the flow, restrict the discharge.

Do not restrict the intake. Doing so will starve the
pump for water and can cause overheating.

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

1/2" Hose
Connection

3/4" Hose
Connection

Plug

Fountain
Jet

Diverter
Valve

Clamp

Clamp

Connector

Hose to
Waterfall
(Purchase
separately)

Adapter

Accessory  Kit FPWG-A68

(Purchase Separately) 

For use with the 1200, 2300
and 3000 Series Pumps   

3384 0399 A

1-1/4"x1" NPT
Adapter

1" NPT" to 
Garden Hose 
Adapter

3384 0399 B

Model Numbers
FPOS1200X,
FPOS2300X
FPOS3000X
Include three
different adapters

FPOS4100X
Includes one
adapter

Pumps include the adapters below.

1-1/4"x1" NPT
Adapter

 1", 3/4" or
1/2" Barbed
Hose Adapter 

Figure 2: Typical Installation Setup. Models FP0S1200X,
FP0S2300X, and FP0S3000X include 3 adapters shown.
Model FP0S4100X includes 1-1/4” x 1” NPT adapter
only.