background image

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Operation

Operating the angle die grinder

 

This Angle Die Grinder is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 

Installing the grinding stone 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

 

Loosen the collet nut with the spanner wrenches enclosed.

 

Insert the grinding stone in the collet. If using a 1/8 in. collet 
stone, an adapter (not included) must be inserted before 
placing the stone into the tool.

 

Tighten the collet nut with the two spanner wrenches.

Removing the grinding stone 

 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

 

Loosen the collet nut with the spanner wrenches.

 

Pull the grinding stone out and tighten the collet nut with the 
spanner wrenches.

Grinding and deburring 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

[rotective respirator is recommended.

 

Connect the angle die grinder to the air supply.  

 

This tool features the safety lock-off mechanism.

 

Operate the tool by disengaging the lock-off mechanism 
and depressing the throttle lever to run the tool for grinding 
or deburring. 

Summary of Contents for Universal Tool UT8715-20

Page 1: ...Read and understand operation instructions Always become familiar with all the instructions and warnings before operating any pneumatic tool TABLE OF CONTENTS General Safety Information 2 Air Compres...

Page 2: ...used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis r...

Page 3: ...s type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as dust masks that are specifically designed to filter out microsc...

Page 4: ...y check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding th...

Page 5: ...in collet stone an adapter not included must be inserted before placing the stone into the tool Tighten the collet nut with the two spanner wrenches 3 Removing the grinding stone WARNING Disconnect th...

Page 6: ...rease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evid...

Page 7: ...22240 Throttle Valve 1 8 9522208 Spring 1 30 952230 Bevel Gear 1 9 952 522510 Valve Screw 1 31 952231 Lock Ring 1 10 952236 O Ring 1 32 9522250 Damping Material 1 11 952212 Rotor Spacer 1 33 952233 Sp...

Page 8: ...matic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMA...

Reviews: