FLORIDA-PNEUMATIC.COM
Please contact 1-800-356-3392 for further assistance.
Operation
1
Operating the hammer
□
This Hammer is designed to operate on 90 PSIG. Lower
pressure (below 90 PSIG) will reduce performance of
the tool. Higher air pressure (over 90 PSIG) raises the
performance of the tool beyond its rated capacity and
could cause serious damage to the tool and the user.
2
Installing the chisel
WARNING:
Disconnect the tool from the air supply before
servicing or changing accessories.
□
To insert the chisel, press the loop on the retainer spring
to the side and push the chisel into the cylinder of the air
hammer. Release the loop.
□
Ensure the chisel is properly held by the retainer spring
before use.
3
Removing the chisel
□
Rotate the spring counterclockwise to remove the retainer
spring.
□
Pull the chisel out of the air hammer.
WARNING:
Do not operate the tool without the chisel in
cylinder or allow the chisel to be driven out of the cylinder. Internal
damage will result if the piston strikes the cylinder wall.
4
Operating the air hammer
□
Place the cutting edge of the chisel against the work piece
and then press the trigger.
□
Do not operate percussion tools unless chisel or rivet set is
against the work piece.