background image

Universal Tool a Division of Florida Pneumatic Mfg. Corp.  

851 Jupiter Park Lane, Jupiter FL 33458

Universal Air Tools Company Ltd.

 

Unit 8 Lane End Industrial Park, High Wycombe, HP14 3BY, UK

Operation

Operating the needle scaler

 

This needle scaler is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user.

Needle replacement

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

 

 

 

 

Grip needle tube at knurled portion and turn counter 

clockwise until it loosens from the barrel.  Remove and 

replace needles in needle holder making sure all needles 

are inside the spring before reassembling.

Operating the needle scaler

 

Always place needles against the work surface before 

depressing the throttle lever.  Free air operation of this tool 

can damage internal components. 

Summary of Contents for Universal Tool UT8633

Page 1: ...ions and warnings before operating any pneumatic tool TABLE OF CONTENTS General Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication...

Page 2: ...essential If the pneumatic tool is used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth...

Page 3: ...a from bricks and cement and other masonry products arsenic and chromium from chemically treated lumber Your risk from those exposures varies depending on how often you do this type of work To reduce...

Page 4: ...e tool from operating if the throttle is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regu...

Page 5: ...mance of the tool beyond its rated capacity and could cause serious damage to the tool and the user 2 Needle replacement WARNING Disconnect the tool from the air supply before servicing or changing ac...

Page 6: ...nd grease the bearing with bearing grease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the too...

Page 7: ...Qty Ref Part Number Description Qty 1 288 01 BACKHEAD 1 11 288 11 PISTON 1 2 288 02 O RING 1 12 288 12 BARREL SLEEVE 1 3 288 03 THROTTLE VALVE 1 13 288 13 O RING 2 4 288 03 1 O RING 1 14 288 14 NEEDLE...

Page 8: ...rsal Air Tools Company Ltd Unit 8 Lane End Industrial Park High Wycombe HP14 3BY UK sales universal co uk www universal co uk Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 Univers...

Reviews: