Installation

Cleaning the air hose

 

A 3/8" air hose is required, with a maximum length of 25 ft. 

 

Clean the air hose of accumulated dust and moisture 
before connecting it to the air supply.

NOTE:

 If a longer air hose is required, connect a 1/2" air 

hose to the 3/8" air hose to ensure the impact wrench has 
the necessary air supply.

Recommended Air Line Set-Up

Part

Description

A

Air Tool

B

Quick Plug

C

Quick Coupler

D

Air Hose

E

In-line Regulator

F

In-line Lubricator

G

In-line Filter

H

Air Compressor

Maintenance

Ensure the air line is shut-off and drained of air before removing this tool for service or changing sockets. This will 
prevent the tool from operating if the throttle is accidentally engaged.

LUBRICATION

 

An in-line filter-regulator-lubricator is recommended as it increases tool life and keeps the tool in sustained 
operation. 

 

Regularly check and fill the in-line lubricator with air tool oil. Avoid using excessive amounts of oil.

 

Adjust the in-line lubricator by placing a sheet of paper next to the tool’s exhaust ports and holding the throttle 
open approximately 30 seconds. The lubricator is properly set when a light stain of oil collects on the paper. 

 

If it is necessary to store the tool for an extended period of time (overnight, weekend, etc.), generously lubricate the tool through the air 
inlet. Run the tool for approximately 30 seconds to ensure the oil is evenly distributed throughout the tool. Store the tool in a clean and 
dry environment. 

 

Recommended lubricants: Air tool oil or any other high grade turbine oil containing moisture absorbent, rust inhibitors, metal wetting 
agents, and an EP (extreme pressure) additive.

Summary of Contents for FP-720B

Page 1: ...nderstand operation instructions Always become familiar with all the instructions and warnings before operating any pneumatic tool General Safety Information 2 Air Compressor and Air Tool Safety 2 3 T...

Page 2: ...a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis risk asse...

Page 3: ...ety equipment such as dust masks that are specifically designed to filter out microscopic particles Specifications Important Warnings Impacts 1 Eye protection and hearing protection and safety gloves...

Page 4: ...throttle is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regularly check and fill the in...

Page 5: ...and the position with the largest circle has the most amount of power The settings on the regulator are only for reference and do not denote a specific power output 4 Tightening loosening the bolts o...

Page 6: ...essure is low Adjust the regulator on the tool to the maximum setting Adjust the compressor regulator to the tool s maximum setting of 90 psi The air hose leaks Tighten and seal the hose fittings with...

Page 7: ...loded View Drawing 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1 2 1 1 1 2 2 2 2 2 1 1 1 1 2 1 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9...

Page 8: ...atic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMATIC COM Retain t...

Reviews: