PEDESTAL TO OPL CABINET INSTALLATION
PART #
DESCRIPTION
91079
FLOATING SHELF
91121
PEDESTAL
86101
3/8-16 X 1.25 CARRIAGE BOLT
86097
3/8” X .688 OD LOCK WASHER
86089B 3/8-16 HEX NUT
K86101-F KIT HARDWARE PEDESTAL TO UNIT
MOUNTING (INCLUDES CARRIAGE
BOLTS, LOCK WASHERS AND HEX
NUTS)
REQUIRED TOOLS
9/16” SOCKET WRENCH
Open master access door and lift handle to open master loading door(s).
Remove 91079 floating shelf(ves), exposing mounting holes.
Place unit on pedestal.
From underneath unit, insert four (4) 86101 carriage bolts upward.
From inside parcel compartment(s), add four (4) 86097 lock washers and tighten four (4)
86089B hex nuts. Torque to 22 foot-pounds.
Replace 91079 floating shelf(ves).
Close master loading doors by first lifting slightly on the master hold open arm and then shutting
each door.
Installation of unit is now complete. Contact local USPS personnel to install Arrow Locks and
place unit into service.