background image

DM-2680 Safety & Operators Manual 

1800 FLOOREX 

PAGE 4.                      1800 356 673 

Filter Cleaning 

1. 

The Dust Extractor has a filter cleaning system that 
operates when the filter cleaning knob is activated. 

2. 

In normal operation, the filters will be sufficiently cleaned 
without the need for any manual filter cleaning such as 
washing the pleats directly. 

3. 

Do not use compressed air to clean any filter as it can 
damage the media and allow dust to enter the motor. 

4. 

This Rotary Filter Cleaning System is very effective and 
takes only 10-20 seconds to deep clean the filter when the 
suction motors are turned off.  

5. 

The rotary filter cleaning is best performed when the motors 
are both stopped. But can assist in the cleaning during 
operation while the machine is in operation. 

6. 

Above all please contact your supplier if you have a 
concern. 

 
 
 
 

 

Summary of Contents for DM-2680

Page 1: ...DM 2680 Safety Operators Manual ...

Page 2: ...0 Safety Operators Manual 1800 FLOOREX PAGE 1 1800 356 673 Table of Contents Contents Table of Contents 1 Safety Instructions 2 Filter Cleaning 4 Operating Instructions 5 Electrical Safety 7 Problem Solving 9 ...

Page 3: ...ion 5 For the operators safety and the safety of others always keep all guards and shrouds in place 6 This the Dust Extractor is intended for use with concrete dust 7 Do not lend or rent the Dust Extractor without the operating instructions for the Dust Extractor 8 Wear clothing suitable for the job and for the work place including safety shoes hard hat hearing protection non fogging vented safety...

Page 4: ...an cause severe and permanent lung damage cancer and or other serious diseases Do not breathe the dust Do not rely on your sight or smell to determine if dust is in the air Silica may be in the air without a visible dust cloud If air monitoring for silica is not provided by your employer at your work site you must wear appropriate respiratory protection when operating or maintaining this equipment...

Page 5: ...washing the pleats directly 3 Do not use compressed air to clean any filter as it can damage the media and allow dust to enter the motor 4 This Rotary Filter Cleaning System is very effective and takes only 10 20 seconds to deep clean the filter when the suction motors are turned off 5 The rotary filter cleaning is best performed when the motors are both stopped But can assist in the cleaning duri...

Page 6: ...ed via the over center clamps provided before plugging the machine in to power 5 Connect the Dust Extractor to suitable power outlet This is normally 10A If you need to connect using extension cords please consult your supplier to confirm the best size conductor to use 6 Always move the Dust Extractor with the handles and not by pulling the hose Pulling the machine via the hose could make the mach...

Page 7: ... is fairly small like a hand grinder or even a Meteor 250 or a Satellite 480 and Satellite 650 11 Use both motors when using a wand and floor tool to clean the floor 12 The Head can be lowered using the handle lever and locked in place using the pin 13 WARNING Breathable silica may be generated by use and maintenance of this the Dust Extractor Silica can cause severe and permanent lung damage canc...

Page 8: ... Dust Extractor 6 Never connect or disconnect power cables with voltage present or while under load 7 Disconnect all power connections and observe lock out tag out procedures before attempting to carry out any maintenance or repair on any equipment 8 Avoid any contact with any rotating parts or driven parts 9 Never use equipment that has not been tested and tagged including cords 10 Before connect...

Page 9: ...tor to suitable power outlet This is normally 10A If you need to connect using extension cords please consult your supplier to confirm the best size conductor to use 11 The Dust Extractor can produce sound pressure levels greater than 85db The operator must wear approved safety ear protection ...

Page 10: ...the head is correctly positioned on the main bowl and firmly against the seal If the bucket is not against the seal firmly air can come in and reduce the air flow and or suction The seal is missing at the Bottom Check the seal by eye and feel around the seal area for leaks and replace or re fit If the seals are not correctly fitted or missing the air flow and or suction will be greatly reduced The...

Page 11: ... Manual 1800 FLOOREX PAGE 10 1800 356 673 Warranty Warranty is for a period of 12 months from original purchase date covering manufacturer s defects does not cover brushes on the motor which have an estimated life of 600 hours ...

Page 12: ...0 356 673 Floorex Products Your complete supplier of all your concrete surface preparation needs Diamond grinders Dust extraction Shotblasters Screed mixers Diamond Tooling Floor Scrapers Coating application Web www floorex com au Email sales floorex com au ...