G4SZV-1/G4SZV-2 & G4SDZV-2 V1.10
Page 11
2.8
Liquid Crystal Display
Display is readable at angles ± 45° horizontally as well as vertically at temperatures
within the operating range.
Volume read out f
or the UK is set to the form “xxxxx.yyy” it is not configurable and will
always display leading zeros, as per SECAS rules.
Example: (note leading Zeros may be hidden)
Symbols shown at the top of the display when either the volume or the balance screen is
displayed:
Meaning
Required action
Alarm
Go to the menu, select Actual alarms, and you will
see the alarm
Valve open
No action
Valve busy (opening or closing)
Observe if the gas is disabled
Valve shut
When valve is closed, gas is disabled. Contact gas utility, and
press the button when the meter requires it.
Low Battery
Battery must be exchanged within 30 days.
EC
Emergency Credit Available
Use Menu to accept Emergency Credit to avoid disconnection
EC
Emergency Credit in USE
Emergency Credit is being used
LC
Low Credit
Top up, to avoid incurring Debt or being cut off
ND
Non Disconnect
The meter is OUT OF CREDIT, and would have disconnected
but will remain on supply, because of the Non Disconnect
period
Message waiting (from Utility)
Go to menu + Message, and scroll through the incoming
messages.
Acknowledge with
Paired to Communication Hub
All ok. If the symbol is not present, there is no connection to
the HAN
Information waiting (from gas
meter)
Go to menu + Information, and scroll through the incoming
Information. Acknowledge with by pressing button below [i]
Firmware download in progress