background image

-

5

-

INSTALLING QS200 METER INTO AN EXISTING TEE INSTALLATION (continued)

Figure 11

Install New QS200 Insert FLOMEC Multi-Tool

PIN HOLE ALIGNMENT 

- For easy pin install

CLEAN LID GROOVE - 

Remove dirt, roots, debris

Figure 10

Remove Old Insert From Tee with FLOMEC Multi-Tool

PRY UP - To break a stuck insert loose

LEVERAGE - To Lift 

insert up and out

DRIVING WEDGE - To lift insert more

Summary of Contents for QS200

Page 1: ...f the meter 5 times the pipe s inner diameter downstream of the meter The pipe needs to be full of irrigation water with no air inside Built up sediment on the QS200 s transducers or large debris can greatly hinder the meter s performance Keep the following in mind when installing Install QS200 at an angle as shown in Figure 1a 1 inch pipe installations will need a larger angle of 45 degrees Flow ...

Page 2: ...sert in the Tee but it is recommended to install the Tee first without the QS200 insert inside This will keep excess PVC cement off of the QS200 insert 2 Clean and apply Primer to pipe ends and tee sockets See Figure 3 3 Apply PVC cement to pipe ends and Tee sockets and quickly assemble the parts while the cement is fluid Follow the cement manufacturer s instructions See Figure 4 NOTE Only use PVC...

Page 3: ...etrofits 1 The Tee insert bore must be clean before installing the insert and the 2 black O rings on the insert should be fully lubricated a The O rings on the outside of the QS200 Retrofit Insert are square profile O rings When installing in another brand of Tee if the insert fits too tight into the Tee replace the square profile O rings with the round profile O rings included with the QS200 Retr...

Page 4: ... or driving wedge between the insert lip and top of the tee to break the insert loose and gain room between the insert lip and tee to use the U formed end to lever the insert up and out 2 An alignment tool to align the pin holes of the new insert with the pin holes in the tee 3 A cleaning tool for clearing debris from the valve box lid groove or other crevices The U formed end is designed for use ...

Page 5: ...all New QS200 Insert FLOMEC Multi Tool PIN HOLE ALIGNMENT For easy pin install CLEAN LID GROOVE Remove dirt roots debris Figure 10 Remove Old Insert From Tee with FLOMEC Multi Tool PRY UP To break a stuck insert loose LEVERAGE To Lift insert up and out DRIVING WEDGE To lift insert more ...

Page 6: ... from the meter to the controller decoder to prevent ground interference Make sure cable length is within controller decoder manufacturer s recommendation 7 Connect the and ends as described in Step 3 of this section of the direct burial cable to the controller s decoder s flow sensor input or port per controller decoder manufacturer s direction Keep in mind that the flow sensor input typical desi...

Page 7: ...to devices as flow sensor instead of flowmeter 1 Make sure line is full of water with no trapped air 2 Flow meter may take a few minutes to start averaging out flow per irrigation controller displays 3 It is recommended to monitor and observe stabilized flow rates before setting control limits Operation QS200 WIRING INSTALLATION continued RED BLACK DBR Y 6 SPLICE KIT FLOW INSERT TO FLOW ON FLOW SM...

Page 8: ...o putting into service Product should never be operated outside its published specifications for temperature or pressure See specifications for your model When applying power adhere to specifications listed in appropriate electronics manual Make sure flow and pressure have been eliminated from process pipe prior to installing or removing product This product is not approved for use with petroleum ...