background image

STEP I

Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out

STEP 2 

Install inlet A and discharge, B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.

STEP 3

Slide rubber mounts fully into 4 mounting tracks.

STEP 4

Mount pump vertically, with pump head down or
horizontally in an ible location. If mounting vertically,

motor up, attach motor mounts first then pump head
mounts, while supporting weight of pump.

STEP 5

Use 1/2” I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.

STEP 6

Install a 1/2” in line strainer #01740-002 in accessible
location between shower drain pan and pump inlet. This
strainer or equivalent is required for pump warranty to be
valid.

INSTALLATION

STEP I

Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.

STEP 2

Use a 10-15 amp rated (lighted) on-off switch on the (+)
positive (red) motor lead.

STEP 3

Install 10 amp fuse protection on the positive lead for the
-143 model, use a 7 amp fuse for the -343 model.

WIRING