INSTALLATION

The Guardian 1000

 uses Radio Frequency (RF) waves for communication to the nearest cellular tower and can 

transmit at several times the power of a hand-held cellular phone. In general, if you can place a cellular telephone call 

in the location where you wish to install the unit, then the Guardian should be able to communicate properly. However, 

because of the inherent characteristics of RF communications, there are certain guidelines that should be followed when 

positioning the unit.

Warning: 
• Do not install the 

Guardian 1000

 where hazardous vapors are present.

• Do not use the Guardian 1000

 where blasting is in progress.

• Electrostatic discharge can damage sensitive electronic components. Be sure to discharge yourself by touching a  

   grounded metal object before opening the unit.

• The unit should be installed in an area free from overhanging metal structures, large obstructions, or equipment which      

   could generate RF or electrical interference.

• Do not install the unit below ground level unless provisions are made for an external antenna.

• Service may be limited in areas that do not have GSM cellular coverage and support SMS (Short Message Service). 

• If the unit is installed in an area with poor signal strength, an external antenna may be required for reliable performance. 

   Please contact FLO-CORP Customer Service to determine your exact needs.

INITIAL INSPECTION

When you receive the Guardian 1000

 unit, thoroughly inspect it for any damage which may have occurred during shipping. If 

there is any damage to the Guardian 1000

, contact the shipping company as soon as possible. Locate the packing checklist 

in the shipping container. Check for any missing items before you begin installation of the Guardian 1000

.

Note: The Guardian 1000

™ 

is shipped with the antenna disconnected. It is located in a separate area within the shipping carton. 

Verify that the antenna is present before proceeding.

Tools Required for Installation:

3/16” Flat screwdriver Large adjustable wrench

STAINLESS STEEL TANK PREPARATION 

Please check the following before installation of the Guardian 1000

:

• A 2-inch diameter threaded opening is required for the installation of a Guardian 1000

.

   Stainless Steel tanks are typically built with one or more 2-inch threaded “bung” opening. The tank’s vent line can be   

   modified to provide both tank venting and access for the Guardian 1000

, if the vent is the only 2-inch threaded opening 

   available. Refer to the procedure below for the installation into a vent line.

• For Ultrasonic Guardian 1000

 installations, verify that there are no obstructions within the tank which could alter the 

   ultrasonic readings.

Summary of Contents for GUARDIAN 1000 G1

Page 1: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 1 GUARDIAN 1000 G1 WIRELESS MONITORING SYSTEM OPERATING INSTRUCTIONS...

Page 2: ...tative for further information NOTE REMOVE ALL PACKING INSERTS BEFORE OPERATING LEVEL TRANSMITTER Authorized Personnel All operations described in this operating instructions manual must be carried ou...

Page 3: ...n GSM or CDMA Digital Wireless Radio RF Approval FCC part 15 approved Frequency Bands GSM 850 1900 MHz WLAN Output Voltage Nominally 24 VDC 5 Output Current Rated from 0 24mA Output Short Circuit Prot...

Page 4: ...atus of all your tanks Includes information regarding level battery life cellular signal strength alarm status and alarm information plus much more Locate one of your tanks or all of your tanks with t...

Page 5: ...unit is installed in an area with poor signal strength an external antenna may be required for reliable performance Please contact FLO CORP Customer Service to determine your exact needs INITIAL INSPE...

Page 6: ...e 90 Elbow as shown in Figure 2 4 Install the Differential Pressure Guardian onto the top of the Tee as shown in Figure 2 POLY TANK PREPARATION Please check the following before installation of the Gu...

Page 7: ...rdian 1000 Therefore the location of the Guardian 1000 bottom in relation to the opening of the tank is critical CAUTION The bung opening must be plumb in reference to the overall tank The distance fr...

Page 8: ...is NOT a good installation since the Guardian cannot be mounted plumb In this type of installation the ultrasonic signal will not bounce directly from the product back to the sensor but will instead b...

Page 9: ...s typically the tank volume up to the Top Tangent Line Any dome or dish on the top of the tank is not included in the capacity determination The orientation of the tank below the Bottom Tangent Line c...

Page 10: ...current loop For applications where the Guardian 1000 will be powering the current loop the wiring needs to be moved to 24 and IN Refer to the three illustrations below for three wiring configuration...

Page 11: ...scenario the Guardian 1000 is wired into an existing established current loop on the positive side between the current loop source and the instrumentation GUARDIAN PLACED IN SERIES WITH EXISTING CURR...

Page 12: ...he tank the GSM SMS Short Message Service is available signal strength has been verified and the number of callouts per day has been properly set it is now time to establish communications with the FL...

Page 13: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 13...

Page 14: ...dically To obtain the latest details on how to use the new features of the web site follow the links to the help section of the web site ACCESSING MonitorMyGuardian com On your PC smart phone or table...

Page 15: ...e antenna is tightly connected to the unit and is vertical If still not successful contact FLO CORP Customer Service for confirmation of data channel availability 5 Cellular Busy Error The Guardian co...

Page 16: ...e set up by your FLO CORP account representative when the tank is initially configured On rare occasions the information may not be correctly entered If you have verified the tank information and the...

Page 17: ...expired batteries and pack Never mix fresh batteries with partially or fully expired batteries 4 Insert new batteries into the battery sockets located on the printed circuit card and install the new...

Page 18: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 18...

Page 19: ...m left to right to construct your FLO CORP Model Number Simply match the category number to the corresponding box number G1 Example G1 1 GP NN Guardian 1000 Wireless Monitoring System with GSM Host 4...

Reviews: