FLIR SR-100A Installation And Operation Manual Download Page 1

427-0042-00-10 Revision 130                       Copyright © 2011 FLIR Systems, Inc.  

 

 

 

 

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

a

a

n

n

d

d

 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

 

 

 

FLIR Systems, Inc. 
70 Castilian Drive 
Goleta, CA 93117 
Phone: 888.747.FLIR (888.747.3547) 
International: +1.805.964.9797 
http:// www.flir.com 

Camera Models 

SR-124    SR-117    SR-112  
SR-348    SR-334    SR-324   
SR-313    SR-309    SR-304 
SR-645    SR-625    SR-618   

SR-612    SR-606 

Summary of Contents for SR-100A

Page 1: ...a an nd d O Op pe er ra at ti io on n M Ma an nu ua al l FLIR Systems Inc 70 Castilian Drive Goleta CA 93117 Phone 888 747 FLIR 888 747 3547 International 1 805 964 9797 http www flir com Camera Model...

Page 2: ...a subject to this restriction are contained in all sheets of this document and related drawings and document specifications herein FLIR reserves the right to make changes to its products or specificat...

Page 3: ...ations 11 3 5 Sealed Cable Glands 12 3 6 Analog Video Output 13 3 7 Camera Mounting 13 4 INSTALLATION 14 4 1 Open Camera Enclosure 14 4 2 DIP Switch Settings 15 4 3 Camera Installation 16 5 OPERATING...

Page 4: ...ure 8 Figure 3 1 Rear view of SR Series camera 9 Figure 3 2 Earth Ground Connection 10 Figure 3 3 Serial Communications Options 11 Figure 4 1 Front view of SR Series camera 14 Figure 4 2 Serial Commun...

Page 5: ...aws that vary from country to country Check the laws in your local region before using this product for surveillance purposes Support If you have questions that are not covered in this manual or need...

Page 6: ...g the thermal image on the right provides clear details The SR Series camera is designed for simple intuitive installation and operation Each model is based on the widely deployed uncooled microbolome...

Page 7: ...he FLIR web site http www flir com cvs cores resources Figure 2 2 White Hot palette on left Black Hot palette on right 2 2 SR Series Camera Models The cameras are available with a choice of lenses for...

Page 8: ...a lens heater to provide sharp imagery in all temperature and weather conditions ensuring a clear lens and high quality infrared video even in extremely cold environments Figure 2 3 SR 309 Camera wit...

Page 9: ...Series camera It is necessary to remove the rear of the enclosure in order to access the electrical connections The SR Series provides electrical contacts in the form of screw terminal jacks allowing...

Page 10: ...inals for receiving tinned leads for input power The power cable should be twisted pair or triple with an overall shield or conduit connected to the enclosure rear panel ground lug as described in the...

Page 11: ...a is configured for RS 232 protocol then it may be directly attached to a PC or laptop running the FLIR Camera Controller graphical user interface GUI software which is included with the camera or dow...

Page 12: ...ble should be inserted through the cable gland on the right Leave the glands loosened until the cable installation has been completed Inspect and install gland fittings with suitable leak sealant and...

Page 13: ...systems camera signals must travel from the camera to the monitor Proper termination of cables is essential to a system s reliable performance The end point of any video cable run must be terminated i...

Page 14: ...ies cameras come pre configured for RS 232 communication from the factory and the installer may change the option via a DIP switch The switch would only need to be accessed if changing from the defaul...

Page 15: ...0 ohm termination resistor set to On for RS 422 Removes termination resistor set to Off for RS 232 communications 2 Enables RS 232 communication Enables RS 422 communication Note Daisy chaining of cam...

Page 16: ...ads attach to the detachable connector according to Table 1 Power and Serial Pin Designations Note the pin numbers are not designated on the connector Connector Pin Used for Power or Serial Communicat...

Page 17: ...ferred RS 232 or RS 422 configuration 3 Make sure that the O rings supplied on the front and rear covers of the camera enclosure are free of dirt and debris before reassembly The O rings are lubricate...

Page 18: ...Earth Ground Lug on the inside of the rear of the enclosure refer to Figure 3 2 Earth Ground Connection 6 Insert the enclosure sled and rear plate into the enclosure body Press the two components tog...

Page 19: ...setting sun in the backlit image on the left makes it difficult to discern any objects of interest the thermal image on the right is not affected by the bright sun and therefore provides detail and c...

Page 20: ...with familiar objects will be easy to interpret with some experience The camera automatically optimizes the image to provide you with the best contrast in most conditions FLIR Systems Inc offers a co...

Page 21: ...rface 6 1 Temperature The SR Series camera has an operating temperature range of 40 to 55 C Choose an installation location so that the camera is not subject to temperature extremes that exceed this r...

Page 22: ...on among others and must be carefully matched to the specific application Moreover the transmission characteristics of the cable will be influenced by the physical environment through which the cable...

Page 23: ...scene during this time will be quite noticeable and cause the AGC to produce a high contrast image Eastern or Western Exposure Some users will choose to mount the camera pointing directly east or west...

Page 24: ...pitch SR 1xx SR3xx 25 m SR 6xx 17 m Input power range 14V to 32VDC Voltages as measured at the input to the 18V to 27VAC electrical interface board Fuse 4 Amp fast blow mini blade fuse Ex Bussman BK...

Page 25: ...24 VAC SR 618 313 at 24 VAC SR 309 612 at 24 VAC SR 606 304 at 24 VAC DC Input Voltage 14 to 32 VDC Voltage as measured at the input to the electrical interface board Nominal Peak Current TRMS 100 410...

Page 26: ...1 Camera Side View Figure 8 2 Camera Rear View Dimension All cameras except SR 304 SR 606 SR 304 SR 606 Length 10 5 26 7 15 38 14 Width 5 0 12 7 5 0 12 7 Height 5 7 14 4 5 68 14 4 Weight 4 6 lb 2 1 k...

Page 27: ...Enclosure Product Specification NTSC EIA 170 PAL CCIR 624 MIL STD 810E Environmental Testing MIL STD 188 124B Grounding Bonding and Shielding IEC 60529 Degrees of protection provided by enclosures IP...

Page 28: ...ems Inc 28 Support If you have questions that are not covered in this manual or need more information contact your local FLIR service representative or 1 877 773 3547 inside the US In the US you can r...

Reviews: