background image

FLIR

 

MR176

 ‐ 

GETTING

 

STARTED

                                                                                                                                  

Document

 

Identifier:

 

MR176

QS

mul_AA

 

Fig.

 

5

 

(a)

 

IGM Moisture

 

mode

                      

Fig.

 

5

 

(b)

IGM

 

Custom

 

mode

MAIN

 

Menu

 

Press

 

the

 

Select

 

button

 

to

 

access

 

the

 

Main

 

Menu

 

(Fig.

 

2)

 

and

 

to

 

select

 

icons.

 

Use

 

the

 

four

 

navigation

 

buttons

 

to

 

move

 

left

right

up

down.

 

Use

 

the

 

Back

 

button

 

 

to

 

move

 

out

 

of

 

a

 

menu.

 

1.

 

Image

 

Review

 

mode

 

(view

 

and

 

deleted

 

stored

 

display

 

images)

 

2.

 

Image

 

mode

 

selection

 

3.

 

Moisture

 

mode

 

selection

 

and

 

options

 

4.

 

Lock/Unlock

 

Palette

 

auto

scaling

 

5.

 

Settings

 

menu

 

IMAGE

 

Mode

 

Selection

 

Press

 

Select

 

to

 

access

 

the

 

Main

 

Menu

 

and

 

then

 

select

 

the

 

IMAGE

 

mode

 

icon

 

(1).

 

See

 

Fig.

 

3.

   

1.

 

Image

 

mode

 

icon

 

from

 

the

 

Main

 

Menu

 

2.

 

IR

 

Thermal

 

Image

 

mode

 

only

 

3.

 

IGM

 

Custom

 

mode:

 

IR

 

Thermal

 

image

 

and

  

a

 

custom

 

set

 

of

 

parameters

 

(Moisture,

 

Air

 

Temperature,

 

RH%,

 

Dew

 

Point,

 

Mixing

 

Ratio,

 

and

 

Vapor

 

Pressure);

 

configurable

 

in

 

the

 

Settings

 

menu.

 

4.

 

IGM

 

Moisture

 

mode

 

(IR

 

Thermal

 

image

 

and

 

Moisture

 

reading)

 

5.

 

Psychrometrics

 

screen.

 

Displays

 

Air

 

Temperaure,

 

RH%,

 

Dew

 

Point,

 

Mixing

 

Ratio,

 

&

 

Vapor

 

Pressure

 

6.

 

Moisture

 

reading

 

with

 

bargraph

                

 

MOISTURE

 

Mode

 

Selection

 

Press

 

Select

 

for

 

the

 

Main

 

Menu

 

and

 

select

 

the

 

MOISTURE

 

mode

 

icon

 

(1).

 

See

 

Fig.

 

4.

   

1.

 

Moisture

 

Mode

 

Icon

 

from

 

the

 

Main

 

Menu

 

2.

 

MATERIAL

 

GROUP:

 

Select

 

a

 

material

 

wood

 

group

 

(pin

 

mode);

 

see

 

User

 

Guide

 

for

 

group

 

tables.

 

3.

 

PIN

 

MODE:

 

For

 

external

 

pin

based

 

probe

 

use

 

4.

 

PINLESS

 

MODE:

 

For

 

internal

 

sensor

 

use

 

5.

 

SET

 

REFERENCE:

 

Compare

 

displayed

 

readings

 

to

 

a

 

stored

 

reference

 

(pinless

 

mode

 

only)

 

Settings

 

Menu

  

Access

 

Settings

 

by

 

pressing

 

the

 

Select

 

button

 

and

 

selecting

 

the

 

Settings

 

mode

 

icon

 

1. 

LANGUAGE:

 

From

 

the

 

Settings

 

menu,

 

scroll

 

to

 

Language

 

and

 

press

 

Select.

 

Use

 

the

 

Navigation

 

buttons

 

to

 

scroll

 

to

 

the

 

desired

 

language

 

and

 

then

 

press

 

the

 

Select

 

button.

 

The

 

selected

 

language

 

will

 

show

 

a

 

blue

 

dot

 

to

 

its

 

right.

   

2. 

CONFIGURE

 

IGM

 

CUSTOM:

 

Choose

 

the

 

parameters

 

to

 

display

 

in

 

the

 

IGM

 

Custom

 

Moisture

 

screen

 

(see

 

Image

 

Mode

 

selection

 

section

 

above).

 

3. 

PALETTE:

 

Select

 

the

 

color

 

scheme

 

(Iron,

 

Rainbow,

 

Ice,

 

Grey)

 

for

 

IR

 

Thermal

 

image

 

viewing

 

by

 

pressing

 

the

 

Select

 

button.

 

 

4. 

ALARM

:

 

Scroll

 

to

 

Alarm

 

and

 

press

 

Select.

 

Use

 

the

 

up/down

 

buttons

 

to

 

turn

 

the

 

alarm

 

ON/OFF.

 

Use

 

the

 

left/right

 

buttons

 

to

 

select

 

a

 

threshold

 

digit

 

and

 

then

 

use

 

the

 

up/down

 

buttons

 

to

 

change

 

its

 

value.

 

Press

 

Select

 

to

 

save

 

and

 

return.

 

5. 

AUTO

 

POWER

 

OFF

:

 

Scroll

 

to

 

Auto

 

Power

 

OFF

 

and

 

then

 

use

 

the

 

Select

 

button

 

to

 

step

 

through

 

the

 

options

 

(1,

 

5,

 

20

 

minutes,

 

or

 

OFF).

 

Navigate

 

to

 

another

 

SETTINGS

 

option

 

or

 

press

 

the

 

back

 

button

 

to

 

exit

 

the

 

Settings

 

mode.

 

6. 

UNITS:

 

Select

 

the

 

desired

 

temperature

 

units

 

(

o

C

 

o

F

 

and

 

GPP

 

g/kg)

 

using

 

the

 

Select

 

button.

 

7. 

DATE

 

&

 

TIME

:

 

From

 

the

 

SETTINGS

 

menu,

 

scroll

 

to

 

Date

 

&

 

Time

 

and

 

press

 

Select.

 

Use

 

the

 

Navigation

 

and

 

Select

 

buttons

 

to

 

program

 

the

 

Year,

 

Month,

 

Day,

 

Hour,

 

&

 

Minute.

 

Press

 

Select

 

to

 

save

 

and

 

return

 

to

 

the

 

SETTINGS

 

Menu

 

or

 

press

 

the

 

Back

 

button

 

to

 

cancel.

 

8. 

HELP

 

SCREEN:

 

View

 

technical

 

support

 

and

 

training

 

contact

 

information.

 

9. 

METER

 

INFORMATION

:

 

Scroll

 

to

 

Meter

 

Information

 

and

 

press

 

Select

 

to

 

view

 

the

 

Model,

 

Software

 

Version,

 

and

 

Last

 

Calibration

 

Date.

 

Press

 

the

 

back

 

button

 

 

to

 

return

 

to

 

the

 

SETTINGS

 

menu.

 

Basic

 

Display

 

Descriptions

 

(Refer

 

to

 

Fig.

 

5)

 

IGM

 

Moisture

 

Mode

 

Fig

 

5(a)

 

1.

 

Thermal

 

Image

 

2.

 

Set

 

Relative

 

icon

 

and

 

reference

 

value

 

3.

 

Alarm

 

icon

 

and

 

Alarm

 

Threshold

 

value

 

4.

 

Moisture

 

Mode

 

icon

 

(Pinless

 

mode

 

shown)

 

5.

 

Moisture

 

reading

 

6.

 

Laser

 

pointer

 

icon

 

7.

 

Cross

hairs

 

IGM

 

Custom

 

Mode

 

Fig

 

5(b)

 

1.

 

Thermal

 

image

 

2.

 

Mixing

 

ratio

 

3.

 

Dew

 

Point

 

temperature

 

4.

 

RH%

 

(solid

 

green

 

dot

 

&

 

green

 

reading

 

when

 

stabilized)

 

5.

 

Air

 

Temperature

 

reading

 

6.

 

Moisture

 

mode

 

icon

 

(Pinless

 

mode

 

shown)

 

7.

 

Moisture

 

reading

 

8.

 

Alarm

 

icon

 

9.

 

Set

 

Reference

 

mode

 

icon

 

 

Copyright

 

©

 

2015

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form.

 

www.flir.com

 

1

2

3

3

4 5

Fig.

 

2

 

 

Main

 

Menu

 

1

2

3

4

5 6

Fig.

 

3

 

 

Image

 

Mode

 

1

2

3

4

5

Fig.

 

4

 

 

Moisture

 

Mode

 

1

2

3

4

5 6 7

1

2

3

4

5

6

7 8

9

Reviews: