4226044 (Rev. C) © 2020 FLIR Systems, Inc.
43
FLIR Fido® X4 Operations Manual
sensing element (see 3.5.1), along with alarm thresholds, is displayed. The type of graph is
determined by the Fido X4 Vapor Mode settings (5.4.2).
Search mode does not provide category- or substance -level threat identification. Its main pur-
pose is for sorting out possible threats from "noise."
5.5 Sample Information
You can access additional information for any sample by selecting the
Info
option after an
analysis result is displayed.
5.5.1 Sample information: no threat detected
If no threat was detected, the sample information screen will resemble Figure 5-26:
Figure 5-26
: Sample information screen: No threat detected
Information type
Comments
1
Sensing element type
2
Unique file number
3
Commands
• Select
Data
to view the raw sensor array data in the
form of a spectrogram. See 5.5.3.
• Select
OK
to return to the analysis result screen.
• Select
Flag
to flag the sample record. See 5.5.4.
• Select
ID
for more information on the threat.
See 5.5.5.
4
Current Sensitivity setting
5
Result of analysis
Displays the message "No threat found."
6
Sensitivity setting when
sample was taken