![FLIR FC-Series S Installation Manual Download Page 59](http://html1.mh-extra.com/html/flir/fc-series-s/fc-series-s_installation-manual_2306154059.webp)
427-0073-12-12 Version 120
May 2015
3-15
3
Advanced Configuration
The default TCP port for most FLIR IP cameras is 1001. This is the port number that a client program
such as FSM can use to communicate with the camera. If using an ONVIF-compliant VMS as a client,
refer to VMS Remote, below.
If the Enable Network Broadcast Discovery
parameter is set to Yes, the camera sends
out a “discovery” packet on the network
every half second as an Ethernet broadcast.
To restrict client programs to allowed IP
addresses, enter allowed IP addresses in
the Remote Clients list, then set the Allow
anonymous clients parameter to No, and
click
Save
. The changes will not take effect
until the server is stopped and started.
After the interface is configured, scroll down
and click on the
Save
button to save the configuration. The changes will not take effect until the server
is stopped and started.
It is also possible to restrict access to the camera from a web browser. Refer to
Security Options, pg.
2-15
to add an allowed IP address to the list in the Restrict Web Configuration section.
VMS Remote:
If the camera is used with a third-party VMS that is compliant with ONVIF, the
parameters can be adjusted (if needed) to work with the VMS. The ONVIF (Open Network Video
Interface Forum) is an open industry forum for the development of a global standard for the interface
of network video products. An ONVIF-compliant VMS can be used to control a FLIR camera, display
video, and, for pan/tilt cameras, access up to 50 pan/tilt presets. Refer to the VMS documentation to
determine what parameter values are needed. By default, the camera is configured with a VMS
Remote interface with ONVIF 2.0 parameters (Profile S).
Several types of third-party Video Management System (VMS) systems are supported by FLIR IP
cameras. Because these systems tend to evolve and change over time, contact the local FLIR
representative or FLIR Technical Support to resolve any difficulties or questions about using this
feature.
Set
Enter IP
Scroll
Addresses
down
to No
pulldown
For ONVIF, use
the settings in