13.1
General
A good image depends on several different functions and settings, although some func-
tions and settings affect the image more than others.
These are the functions and settings that you need to experiment with:
• Adjusting the infrared camera focus.
• Adjusting the infrared image (automatically or manually).
• Selecting a suitable temperature range.
• Selecting a suitable color palette.
• Changing the measurement parameters.
• Performing a non-uniformity correction (NUC).
The following sections explain how to work with these functions and settings.
In some situations, you may also want to hide the overlay graphics for a better view.
13.2
Adjusting the infrared camera focus
It is very important to adjust the focus correctly. Incorrect focus adjustment affects how the
image modes work. It also affects the temperature measurement.
13.2.1
Manual focus
You can adjust the focus manually by rotating the focus ring. For more information, see
section 10.4
Adjusting the infrared camera focus manually
13.2.2
Autofocus
You can autofocus the infrared camera by pushing the Autofocus button. For more infor-
mation, see section 10.5
Autofocusing the infrared camera
, page 30.
WARNING
Do not point the camera at the face of a person when you use the autofocus function. You can set the
camera to use a laser distance measurement for the focus adjustment. The laser beam can cause eye
irritation.
Note
You can also assign the autofocus function to the programmable button
. For
more information, see section 10.12
Assigning functions to the programmable button
page 37.
13.2.3
Continuous autofocus
The infrared camera can be set up to perform continuous autofocusing. For more informa-
tion, see section 10.6
WARNING
Do not point the camera at the face of a person when the continuous autofocus function is on. The cam-
era uses laser distance measurements (that are continuous) for the focus adjustments. The laser beam
can cause eye irritation.
#T810190; r. AI/41890/41890; en-US
59
Summary of Contents for Exx series
Page 1: ...User s manual FLIR Exx series ...
Page 2: ......
Page 3: ...User s manual FLIR Exx series T810190 r AI 41890 41890 en US iii ...
Page 4: ......
Page 12: ......
Page 51: ...Handling the camera 10 T810190 r AI 41890 41890 en US 39 ...
Page 54: ...Handling the camera 10 10 15 Lanyard strap 10 15 1 General T810190 r AI 41890 41890 en US 42 ...
Page 226: ...Mechanical drawings 27 See next page T810190 r AI 41890 41890 en US 214 ...
Page 228: ...CE Declaration of conformity 28 See next page T810190 r AI 41890 41890 en US 216 ...
Page 229: ......
Page 234: ...Application examples 29 T810190 r AI 41890 41890 en US 222 ...
Page 275: ......
Page 277: ......