Articulation Setup and Orientation 

 

The articulation direction and orientation may change if the probe is twisted and coiled during use or 
when stored. To re-orient the probe: 

1. 

Place the extended probe on a flat surface 

2. 

Set the tension “F” knob to the left or released position. 

3. 

Set the articulation knob to the center position with the R 

Δ

 and 

Δ

 L labels 

in the horizontal position. 

4. 

Manually adjust the probe and camera to the zero degree position. 

5. 

Rotate the articulation knob clockwise for a 90° bend. 

6. 

If necessary, manually adjust the probe  so that the camera lays flat on the 
surface with a 90° articulation 

7. 

Rotate the articulation knob counter-clockwise and confirm proper 
orientation. 

 
 
 

Charging the Battery 

The AC charger port and charging status LED are located in the bottom access compartment. 
Connect the charger to the probe and observe the color of the LED. Red indicates the battery is 
charging. Green indicates the battery is fully charged. 
 
Note: The rechargeable battery is not user replaceable. 

 
 
 
 

Specifications 

 

Resolution 

640 x 480 pixels 

Length 2m 

(6.6’) 

Outer diameter (O.D.) 

6mm (0.02”) 

Battery 

3.7V rechargeable Li-Polymer 

Focus distance 

2 to 6cm (0.79 to 2.36”)  

Operating Temperature 

-20 to 60°C (-4 to 160°F) 

Storage Temperature 

-40 to 80°C (-40 to 176°F) 

Warranty 1 

year 

 
 
 
 
 
 
 