Articulation Setup and Orientation
The articulation direction and orientation may change if the probe is twisted and coiled during use or
when stored. To re-orient the probe:
1.
Place the extended probe on a flat surface
2.
Set the tension “F” knob to the left or released position.
3.
Set the articulation knob to the center position with the R
Δ
and
Δ
L labels
in the horizontal position.
4.
Manually adjust the probe and camera to the zero degree position.
5.
Rotate the articulation knob clockwise for a 90° bend.
6.
If necessary, manually adjust the probe so that the camera lays flat on the
surface with a 90° articulation
7.
Rotate the articulation knob counter-clockwise and confirm proper
orientation.
Charging the Battery
The AC charger port and charging status LED are located in the bottom access compartment.
Connect the charger to the probe and observe the color of the LED. Red indicates the battery is
charging. Green indicates the battery is fully charged.
Note: The rechargeable battery is not user replaceable.
Specifications
Resolution
640 x 480 pixels
Length 2m
(6.6’)
Outer diameter (O.D.)
6mm (0.02”)
Battery
3.7V rechargeable Li-Polymer
Focus distance
2 to 6cm (0.79 to 2.36”)
Operating Temperature
-20 to 60°C (-4 to 160°F)
Storage Temperature
-40 to 80°C (-40 to 176°F)
Warranty 1
year
Copyright
©
2011 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.
www.extech.com
Revision 2.0 10/11