Measurement Specifications 

Measurement

 

Range

 

Resolution

 

Accuracy

 

Earth Ground 
Resistance 

20



0.01

 

± (2% r 10 digits)  

200

 0.1

 

± (2% r 3 digits) 

2000

 

1

 

Earth Voltage 

Frequency: 40 to 
500Hz

 

0 to 200VAC 

 

0.1V

 

± (3% r3digits)

 

Resistance 

0 to 200k

 

0.1k

 

± (1% r2 digits) 

Overload Protection:

    250 Vrms 

AC Voltage 

40 Hz to 400Hz 

0 to 750V 

1V 

± (1.2% r10 digits) 

Overload Protection: 750 Vrms, Input Impedance: 10M

 

DC Voltage 

0 to 1000V 

1V 

± (0.8% r3 digits) 

Overload Protection: 1000 Vrms, Input Impedance: 10M

 

 

 

 

Kit contents 

           382252 Earth Ground Resistance Meter 
 

2 Ground rods    - zinc plated iron (22cm) 

 

6  - AA alkaline batteries 

 

3 Ground rod test cables  - Red (15m), Yellow (10m), Green(5m) 

 

2 Test leads for Ground Resistance with alligator clips (Red and Green) (1.5m) 

 

2 Test leads for Voltage/Resistance (Black and Red) (1m) 

 User’s 

manual 

 

Cloth Carrying case 

 

 

 

 

 

 

Copyright

 

©

 

2014

2017

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

ISO

9001

 

Certified

 

www.extech.com

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for Extech Instruments 382252

Page 1: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ot use meter outdoors when precipitation is likely Installation Category III Pollution degree 2 Altitude 2000 meters max Ambient conditions 32 to 104o F 0 to 40o C RH 80 max Observe the following inte...

Page 3: ...Voltage Tests 6 Function Selector switch Selects desired range and function Top View 1 V C Input Red 2 P Input Yellow 3 COM E Input Green Display Description 1 Test status Icon 2 Battery Charge indica...

Page 4: ...ction Diagram 1 382252 Meter 2 Green Test Lead E 3 Yellow Test Lead P 4 Red Test Lead C 5 Existing Ground rod 6 P1 Auxiliary Earth Bar 7 C1 Auxiliary Earth Bar Earth Voltage Test 1 Set the Function se...

Page 5: ...the Earth Bar C1 7 4 Set the meter s function switch to the desired resistance range 20 200 2000 5 Zero the range as described in the Zero adjustment procedure above 6 Press the TEST button The icon w...

Page 6: ...o the 1000V DC position 3 Connect the test probes to the circuit under test 4 Note the displayed Voltage value Three terminal Ground Resistance Measurement 1 Using the Red and Green 1 5m test leads wi...

Page 7: ...nd of its lifecycle Cleaning and Storage Periodically wipe the meter s case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for a period longer tha...

Page 8: ...1000V 1V 0 8 reading 3 digits Overload Protection 1000 Vrms Input Impedance 10M Kit contents 382252 Earth Ground Resistance Meter 2 Ground rods zinc plated iron 22cm 6 AA alkaline batteries 3 Ground r...

Reviews: