www.
GlobalTestSupply
.com
Find Quality Products Online at:
[email protected]
Page 1: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 2: ...ot use meter outdoors when precipitation is likely Installation Category III Pollution degree 2 Altitude 2000 meters max Ambient conditions 32 to 104o F 0 to 40o C RH 80 max Observe the following inte...
Page 3: ...Voltage Tests 6 Function Selector switch Selects desired range and function Top View 1 V C Input Red 2 P Input Yellow 3 COM E Input Green Display Description 1 Test status Icon 2 Battery Charge indica...
Page 4: ...ction Diagram 1 382252 Meter 2 Green Test Lead E 3 Yellow Test Lead P 4 Red Test Lead C 5 Existing Ground rod 6 P1 Auxiliary Earth Bar 7 C1 Auxiliary Earth Bar Earth Voltage Test 1 Set the Function se...
Page 5: ...the Earth Bar C1 7 4 Set the meter s function switch to the desired resistance range 20 200 2000 5 Zero the range as described in the Zero adjustment procedure above 6 Press the TEST button The icon w...
Page 6: ...o the 1000V DC position 3 Connect the test probes to the circuit under test 4 Note the displayed Voltage value Three terminal Ground Resistance Measurement 1 Using the Red and Green 1 5m test leads wi...
Page 7: ...nd of its lifecycle Cleaning and Storage Periodically wipe the meter s case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for a period longer tha...
Page 8: ...1000V 1V 0 8 reading 3 digits Overload Protection 1000 Vrms Input Impedance 10M Kit contents 382252 Earth Ground Resistance Meter 2 Ground rods zinc plated iron 22cm 6 AA alkaline batteries 3 Ground r...