FLIR EM54 Quick Start Download Page 4

  EM54-QS-en-US_AA 

Area Equations 

 

CFM (ft

3

/min) = Air Velocity (ft/min) x Area (ft

2

CMM (m

3

/min) = Air Velocity (m/sec) x Area (m

2

) x 60 

Battery Replacement 

Switch the meter OFF and remove the screw that secures the rear battery 
compartment. Open the compartment and replace the 9V battery, observing 
correct polarity. Re-assemble the meter before use. 

LCD Backlight 

Short press the backlight button

 

 

to switch the backlight ON/OFF. 

Data Hold 

Short press 

to access/exit the Data Hold mode. Data Hold freezes the 

displayed reading. The 

HOLD

 icon will appear while in the Data Hold mode. 

MAX-MIN-AVG Recording 

Short press 

MAX|MIN|AVG

 to start recording (REC) and to step through 

maximum, minimum, and average readings. Long press 

MAX|MIN|AVG

 to exit. 

3-Year Limited Warranty 

This product is protected by FLIR’s 3

-Year Limited Warranty. Visit  

www.flir.com/testwarranty

 to read the 3-Year Limited Warranty document. 

Register your product at the website to receive a free 1-year warranty 
extension. 

User Manual

 

Visit 

https://support.flir.com

 (

download

 tab) to download the User Manual 

and Quick Start with translations. The User Manual includes detailed 
specifications and instructions. 
 
 