4.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type and length
• Unless otherwise stated use only standard cables of the correct type, supplied by
FLIR.
• Ensure that any non-FLIR cables are of the correct quality and gauge. For example,
longer power cable runs may require larger wire gauges to minimize voltage drop
along the run.
Routing cables
Cables must be routed correctly, to maximize performance and prolong cable life.
• Do NOT bend cables excessively. Wherever possible, ensure a minimum bend
diameter of 200 mm (8 in) / minimum bend radius of 100 mm (4 in).
• Protect all cables from physical damage and exposure to heat. Use trunking or
conduit where possible. Do NOT run cables through bilges or doorways, or close to
moving or hot objects.
• Secure cables in place using tie-wraps or lacing twine. Coil any extra cable and tie
it out of the way.
• Where a cable passes through an exposed bulkhead or deckhead, use a suitable
watertight feed-through.
• Do NOT run cables near to engines or fluorescent lights.
Always route data cables as far away as possible from:
• other equipment and cables,
• high current carrying AC and DC power lines,
• antennae.
Strain relief
Ensure adequate strain relief is provided. Protect connectors from strain and ensure
they will not pull out under extreme sea conditions.
Circuit isolation
Appropriate circuit isolation is required for installations using both AC and DC current:
• Always use isolating transformers or a separate power-inverter to run PC’s, processors,
displays and other sensitive electronic instruments or devices.
• Always use an isolating transformer with Weather FAX audio cables.
• Always use an isolated power supply when using a 3rd party audio amplifier.
• Always use an RS232/NMEA converter with optical isolation on the signal lines.
• Always make sure that PC’s or other sensitive electronic devices have a dedicated
power circuit.
36
Summary of Contents for E70353
Page 2: ......
Page 4: ......
Page 8: ...8 ...
Page 14: ...14 ...
Page 31: ...3 9 Product dimensions M100 M200 Series Planning the installation 31 ...
Page 34: ...34 ...
Page 48: ...Multi camera system with video monitor two Raymarine MFDs two JCUs and a web browser 48 ...
Page 50: ...50 ...
Page 80: ...80 ...
Page 84: ...84 ...
Page 92: ...92 ...
Page 101: ......
Page 103: ......