background image

 
 
 

 
 
 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for CM275

Page 1: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...her Display Icons 12 5 METER POWER 13 5 1 Powering the Meter 13 5 2 Auto Power OFF APO 13 5 3 Battery Type Selection 13 6 MENU SYSTEM 14 6 1 Using the Menu System 14 6 2 Main Menu Options 14 6 2 1 Ima...

Page 3: ...9 3 Data Hold 22 9 4 VFD Mode Low Pass Filter 22 9 5 MAX MIN Mode 23 9 6 DCA Zero Mode 23 9 7 Datalogger 23 9 8 Current and Frequency Measurements 25 9 9 Clamp Adaptor FLEX Current and Frequency Measu...

Page 4: ...6 12 3 Disposal of Electronic Waste 36 13 SPECIFICATIONS 37 13 1 General specifications 37 13 2 Thermal Imaging Specifications 38 13 3 Electrical Specifications 39 14 TECHNICAL SUPPORT 43 15 WARRANTY...

Page 5: ...herein are used for identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactured h...

Page 6: ...e the batteries before you remove the test leads This can cause damage to the instrument and can cause injury to persons Do not use the device if the test leads and or the device show signs of damage...

Page 7: ...ded This symbol adjacent to another symbol or terminal indicates that the user must refer to the user manual for further information This symbol adjacent to a terminal indicates that under normal use...

Page 8: ...system High power work lights built in Auto Range True RMS AC DC 600 A capability Auto Range True RMS AC DC 1000 V capability Frequency AC bandwidth 45 400Hz Frequency Measurements to 60KHz Flex clamp...

Page 9: ...ess 6 Rotary function switch 7 COM negative Probe Input jack 8 Positive Probe Input jack 9 Image Save button short press 10 Return Exit button 11 IGMTM button short press 12 Color TFT Display 13 Clamp...

Page 10: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 11: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 12: ...AC current or voltage DC current or voltage Continuity Resistance Diode V Voltage A Current Amperes F Farad for Capacitance Hz Hertz Frequency 103 kilo 10 3 milli 10 6 micro OL Out of Range warning Ba...

Page 13: ...meter enters sleep mode after a programmable period of inactivity to customize this setting please see Section 7 1 2 APO Auto Power OFF The default time out is 10 minutes The time can be set to 1 2 5...

Page 14: ...use 6 2 Main Menu Options 6 2 1 Image Mode This Image mode icon is only available in the thermal imaging mode The Image mode has two options Image Clamp mode default Display will show Clamp meter dat...

Page 15: ...nsfer data logs and images directly to your PC When connected to a PC use t external storage drive For More detailed information see Section 7 1 9 Delete all Datalogger Readings Section 7 1 10 Delete...

Page 16: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 17: ...nguage and press OK Press to exit 7 1 9 Delete all Datalogger readings Press OK to delete all datalogger records The meter will ask for confirmation 7 1 10 Delete all Stored Images Press OK to delete...

Page 18: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 19: ...s for targeting These can be switched ON or OFF in the Thermal Settings Menu 5 In the Thermal imaging mode the meter continues to operate normally as a Clamp Meter Note that in the Thermal Imaging mod...

Page 20: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 21: ...before radiometric data can be captured To view radiometric data within captured thermal images copy the images to a PC and view using FLIR Tools To view stored images 1 Press OK to open the Main Men...

Page 22: ...button To change the range press the button repeatedly until the desired range is displayed 2 To return to the Auto range mode long press the button until the Auto Range indicator is again displayed...

Page 23: ...Datalogger Log up to 40 000 total reading Each time the datalogger is started a new memory set is opened and the previous one is archived To start logging 1 Press OK to access the main menu 2 Press O...

Page 24: ...ata logs to a remote device running the FLIR Tools software suite Refer to Section 10 Bluetooth Communication for more information 2 press OK Two icons will appear on the bottom of the display for tra...

Page 25: ...using the button If measuring DC Current be sure to ZERO the display per Section 9 6 DCA Zero Mode 4 To manually select the measurement range scale press the button repeatedly Refer to Section 9 1 Au...

Page 26: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 27: ...nt function Current detection threshold is 0 5A for 60 00A Current detection threshold is 5A for 600 0A Inrush current mode is available when measuring AC current 1 Press OK to access the main menu 2...

Page 28: ...tive COM terminal and the red probe lead into the positive terminal Refer to Fig 9 4 below 3 Use the button to select AC or DC measurement The indicator appears for AC measurements The indicator appea...

Page 29: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 30: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 31: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 32: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 33: ...th BLE device running FLIR Tools can find and connect to the CM275 2 When successful communication between the meter and a remote device or FLIR camera is established the Bluetooth icon appears on the...

Page 34: ...he imminent international adoption of DIN 54190 3 Non destructive testing Thermographic testing Part 3 Terms and definitions Material Emissivity Material Emissivity Asphalt 0 90 to 0 98 Cloth black 0...

Page 35: ...s appear white while the sky puddles of water and other cold objects appear dark or cool Scenes with familiar objects will be easy to interpret with some experience Infrared energy is part of a comple...

Page 36: ...reading WARNING To avoid electrical shock disconnect the meter from any connected circuits remove the test leads from the meter terminals and set the function switch to the OFF position before attempt...

Page 37: ...0 to 50 C 45 RH Storage temperature 4 to 140 F 20 to 60 C Relative Humidity 0 80 RH batteries not installed Temperature coefficient 0 2 specified accuracy C 64 4 F 18 C 82 4 F 28 C Operating altitude...

Page 38: ...tter Stored thermal image radiometry Fully radiometric Laser Pointer Class I red IR Temperature Measurement range 14 F 302 F 10 C 150 C Over and under range indication OL Temperature reading stabiliza...

Page 39: ...verload protection 1000V rms Input impedance 1 AC conversion type AC coupled true RMS responding calibrated to the RMS value of a sine wave input Accuracies are given for sine waves at full scale and...

Page 40: ...erances For non sine waves 50 60 Hz add the following Crest Factor corrections For non sine waves 50 60 Hz add the following crest factor corrections For a crest factor of 1 0 2 0 add 3 0 to the accur...

Page 41: ...range and 5 0A for 600 0A range Overload protection 1000 V rms 600 A rms Integration time is 100 ms Table 13 5 Resistance Continuity and Diode Function Range Accuracy Resistance 1 0 5 dgt Continuity 6...

Page 42: ...nuals Models TA72_TA74 Table 13 8 Flex Clamp Adaptor Function Frequency Function Range Accuracy Frequency Flex 600 0 Hz 0 1 2 dgt 6 000 kHz 10 00 kHz Sensitivity Flex function 3A rms at 30 00A range f...

Page 43: ...275 USER MANUAL Document Identifier CM275 en US_AC 43 14 Technical Support Technical Support Website https support flir com www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSup...

Page 44: ...M275 en US_AC 44 15 Warranty 15 1 FLIR Limited 10 year Warranty Year Warranty Visit https support flir com prodreg to read the Limited 10 Year Warranty document www GlobalTestSupply com Find Quality P...

Reviews: