FLIR CM174 C Reference Manual Download Page 3

FLIR

 

CM174

 

REFERENCE

 

GUIDE

                                                                                                                                            

Document

 

Identifier:

 

CM174

QS

mul_AA

 

CLAMP

 

METER

 

DISPLAY

 

ICONS

 

Maximum

 

reading

 

value

 

(MIN/MAX

 

mode)

 

Ampere.

 

Unit

 

of

 

measure

 

for

 

Current

 

 

Minimum

 

reading

 

value

 

(MIN/MAX

 

mode)

 

Volt.

 

Unit

 

of

 

measure

 

for

 

Voltage

 

Auto

 

range

 

mode

 

Farad.

 

Unit

 

of

 

measure

 

for

 

Capacitance

 

 

Data

 

Hold

 

mode

 

(reading

 

freeze)

 

Hertz.

 

Unit

 

of

 

measure

 

for

 

Frequency

 

 

Battery

 

voltage

 

status

 

10

3

 

(kilo)

 

 

Auto

 

power

 

off

 

function

 

is

 

enabled

 

 

10

3

 

(milli)

 

 

Voltage

 

is

 

>

 

30

 

V

 

DC

 

or

 

AC

 

RMS

 

10

6

 

(micro)

 

 

AC

 

current

 

or

 

voltage

 

VFD

 

mode

 

 

DC

 

current

 

or

 

voltage

 

DC

 

Zero

 

mode

 

 

Continuity

 

function

 

Inrush

 

current

 

mode

 

 

Diode

 

test

 

Flex

 

Clamp

 

Adaptor

 

mode

 

 

Ohm.

 

Resistance

 

and

 

Continuity

 

modes

 

Match

 

Flex

 

Clamp

 

range

 

setting

 

to

 

match

 

the

 

CM174.

 

 

Emissivity

 

symbol

 

 

Lo

 

Z

 

mode

 

 

THERMAL

 

IMAGER

 

and

 

PROGRAMMING

 

MENU

 

IGM

 

button

 

(short

 

press)

 

opens

 

the

 

Thermal

 

Imager

 

(see

 

example).

 

IGM

 

button

 

(long

 

press)

 

opens

 

the

 

Programming

 

Menu

 

(table

 

below).

 

Use

 

arrow

 

keys

 

to

 

scroll;

 

use

 

OK

 

to

 

open

 

a

 

menu/toggle

 

a

 

setting;

 

use

 

the

 

back/return

 

button

 

to

 

exit.

   

Icon

 

Description

 

Options

 

 

Color

 

Palette

 

Iron,

 

Rainbow,

 

&

 

Gray

 

scale

 

 

Emissivity

 

0.30,

 

0.60,

 

0.80,

 

0.95,

 

&

 

custom

 

 

Laser

 

pointer

 

ON

 

or

 

OFF

 

 

Temp.

 

units

 

C

 

or

 

F

 

 

Cross

 

hairs

 

ON

 

or

 

OFF

 

 

Diode

 

modes

 

CLASSIC

 

or

 

SMART

 

mode

 

 

Auto

 

Power

 

OFF

 

OFF,

 

1,

 

2,

 

5,

 

or

 

10

 

minutes

 

Help

 

Screen

 

Contact

 

information

 

 

Information

 

Firmware

 

and

 

calibration

 

info

 

 

 

 

 

1
2

3

4
5

6

7

8

9

10

1.

 

Temperature

2.

 

Thermal

 

Image

 

3.

 

Auto

 

Range

 

icon

 

4.

 

High

 

Voltage

 

alert

 

5.

 

Voltage

 

reading

 

6.

 

Battery

 

status

 

7.

 

Auto

 

Power

 

OFF

 

8.

 

Cross

 

hairs

 

9.

 

Palette

 

scale

 

10.

 

Emissivity

 

setting

 

The

 

Thermal

 

Imager

 

measures

 

a

 

targeted

 

surface’s

 

temperature.

 

Color

 

variations

 

reflect

 

temperature

 

differences:

  

lighter

 

colors

 

=

 

higher

 

temperatures

 

and

 

darker

 

colors

 

=

 

cooler

 

temperatures.

 

The

 

Distance

 

to

 

Spot

 

(target)

 

ratio

 

is

 

30:1

 

so

 

at

 

a

 

distance

 

of

 

30”

 

the

 

target

 

spot

 

is

 

1”.

 

Use

 

the

 

Cross

 

hairs

 

and

 

Laser

 

pointer

 

to

 

optimize

 

surface

 

targeting.

 

WARNING:

 

Do

 

not

 

point

 

the

 

laser

 

beam

 

toward

 

the

 

eyes;

 

prolonged

 

exposure

 

may

 

cause

 

injury.

 

Reviews: