background image

S

ERVICE MATERIAL

 

 

Service kit no.1

 

Article no.: 5200-U1 

for load cells with maximum capacity above 30 t 
with ring spanner 
 
 Parts 

list: 

Description Article 

no. 

Quantity 

KP cable gland M16 x 1,5, clamping range 6.5 – 9 mm 

000163 

9 pcs. 

Silicone cover sealing (red) 

10090 

1 pc. 

Silicon grease, 6 g 

40110 

1 pc. 

Dry tablet 

000075 

2 pcs. 

Gasket 22 x 16 x 1.5 mm 

4400 

9 pcs. 

Gasket 18 x 12 x 1.5 mm 

53159 

1 pc. 

Round cord, 6 mm black 

10101007 

0.01 m 

Plastic blind plug M16 x 1.5 

05282 

1 pc. 

Plastic blind plug M12 x 1.5 

00326 

1 pc. 

Ring spanner for M16 cable glands 

SSG19 

1 pc. 

 
 
 

Service kit no.2

 

Article no.: 5200-U2 

for load cells with maximum capacity above 30 t,  
like service kit no. 1 but without ring spanner SSG19 
 
 
 

Service kit no.3

  

Article no.: 5200-U3 

for load cells with maximum capacity in the range from 7.5 t to 22.5 t 
with ring spanner 
 
 Parts 

list: 

 

 

Description Article 

no. 

Quantity 

KP cable gland M16 x 1,5, clamping range 4 – 6.5 mm 

000917 

9 pcs. 

Silicone cover sealing (red) 

10090 

1 pc. 

Silicon grease, 6 g 

40110 

1 pc. 

Dry tablet 

000075 

2 pcs. 

Gasket 22 x 16 x 1.5 mm 

4400 

9 pcs. 

Gasket 18 x 12 x 1.5 mm 

53159 

1 pc. 

Round cord, 6 mm black 

10101007 

0.01 m 

Plastic blind plug M16 x 1.5 

05282 

1 pc. 

Plastic blind plug M12 x 1.5 

00326 

1 pc. 

Ring spanner for M16 cable glands 

SSG19 

1 pc. 

 
 
 

Service kit no.4

  

Article no.: 5200-U4 

for load cells with maximum capacity in the range from 7.5 t to 22.5 t 
like service kit no. 3 but without ring spanner SSG19 
 

Junction Box Type KPF – Technical Manual, Rev. 1.11   July 2008

 

Page 8 of 8

Summary of Contents for KPF-4

Page 1: ...Junction Box Type KPF 4 KPF 6 KPF 8 KPF 10 T TE EC CH HN NI IC CA AL L M MA AN NU UA AL L Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Page 2: ...the use of any options or any consumable products other than those designated as Original FLINTEC Products NOTICE The contents of this manual are subject to change without notice Copyright 2007 by Fli...

Page 3: ...4 MECHANICAL INSTALLATION 4 ELECTRICAL CONNECTIONS 4 LOAD CELL CABLE CONNECTION 5 OUTPUT CABLE CONNECTION 5 CORNER CORRECTION AT SCALES WITH FLINTEC LOAD CELLS 6 CLOSING THE JUNCTION BOX 6 SUMMARY OF...

Page 4: ...h is more or less dry and protected from environmental stress The junction box itself has to be mounted with the cable glands showing vertically to the bottom A flooding or any tensile load on the cab...

Page 5: ...ube significantly Unused cable inlets must be closed by the delivered blind plugs If the cable gland nuts are correctly tightened the sealing part of the cable gland must constrict the blind plug sign...

Page 6: ...kg test load 0 1 kg 500 kg x 1100 0 22 Example 2 400 load cell 10 kg corner error with 5000 kg test load 10 kg 5000 kg x 400 0 8 4 Install the correction resistor into the junction box for the corresp...

Page 7: ...ing hole must be closed by a blind plug and a gasket 6 The earth screw must be electrically connected with protective earth potential equalisation For doing this only the upper nut should be loosened...

Page 8: ...ke service kit no 1 but without ring spanner SSG19 Service kit no 3 Article no 5200 U3 for load cells with maximum capacity in the range from 7 5 t to 22 5 t with ring spanner Parts list Description A...

Reviews: