FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 126 of 131
22.
P
ARAMETER
D
EFAULT
T
ABLE
0--
Interface Block
14-
Entries
00-
RS 232C
142
Label No entrance
000
Data Format
3 = BSI
143
Display Refresh Rate
1 = 100ms
001
Baud rate
3 = 9600
2--
Scale Block
003
Address
0
20-
Set up
004
Data length and Parity
0 = 8 bit, no parity
200
Approved
0 = No
005
Checksum
0 = Disable
201
Increased indication
0 = x10 key
006
Carriage Return
1 = Enable
203
Zero range
3 = ± %50
007
Line Feed
1 = Enable
204
Auto zero tracking
0 = Disable
008
Response Speed
0 = immediately
205
Tare
2 = Tare/Clear
01-
RS 485
206
Motion detector
2 =
± 1e
010
Data Format
5 = Modbus RTU Lo-
Hi
(1)
21-
Scale Build
011
Baud rate
3 = 9600
212
Capacity / d
60 kg / 0.01 kg
013
Address
1
214
Unit
0 = kg
014
Data length and Parity
0 = 8 bit, no parity
3--
Calibration Block
015
Checksum
0 = Disable
30-
Calibration
016
Carriage Return
1 = Enable
301
Calibration
017
Line Feed
1 = Enable
302
Linearity Correction
018
Response Speed
0 = immediately
31-
Adjustment
03-
Ethernet
310
Zero adjustment
030
Ethernet Data Format
5 = Modbus RTU Lo-
Hi
311
Span adjustment
031
Ethernet Address
1
312
Span adjustment under load
032
IP Address
192.168.016.250
313
eCal Calibration
033
Subnet Mask
255.255.255.000
5--
Filling Block
034
Gateway Address
192.168.016.253
50-
Filling Parameters
035
Local Port
502
500
Filling mode
1 = Mode-1
036
Response Speed
0 = immediately
501
Feeding type
1
04-
Printer
502
Preact correction factor
50%
040
Print out format
2 = Multi line
503
Preact correction frequency
1
041
CN
1 = Will be printed
504
Check delay
1.0 sec.
042
Minimum print
20
505
Zeroing period
250 sec.
043
Print method
0 = With Print Key
506
Zeroing delay
2.0 sec.
044
Line feed before printing
00 = 0 F + 0 LF
507
Indication at the end of filling
0
045
Line feed after printing
04 = 0 F + 2 LF
508
Feeding check
0
046
Form feed
0 = Disable
509
Filling time
0
047
Space on the left
3
50A
Start Type
0
048
Quantity of copies
1
8--
Metrological Data Block
05-
Profibus DP
80-
Legal Metrology
050
Data Format
0 = signed 32 bit
800
Calibration counter
051
Rack Address
0
9--
Diagnostic
06-
Profinet, EtherNET/IP, EtherCAT, Powerlink
90-
Tests
060
Data Format
0 = signed 32 bit
900
Key Pad testing
07-
CANopen, CC-Link
901
RS 232C testing
070
Data Format
0 = signed 32 bit
902
RS 485 testing
071
Rack Address
0
903
Parallel inputs test
072
Baudrate
0 = 156 kbps
1--
Configuration Block
904
Parallel outputs test
11-
Start Up
905
mV indication
116
Function key
3 = Quantitiy
99-
Printing Parameters
117
Zero output
0 = Gross zero
990
Whole parameters
12-
Filter
991
Load default parameters
120
Filter
7
1)Except for FT-10Fill EN