FAA-27, Technical Manual, Rev. 1.1, June 2014
Page 5 of 21
Meanings of the positions of rotary switches
;
Programming (Prog)
switch
V
Voltage output type run
(refer to page 9)
I
Current output type run
(refer to page 9)
S1
Setpoint 1 adjustment
(refer to page 17)
S2
Setpoint 2 adjustment
(refer to page 17)
Z
Zero adjustment
(refer to page 11)
G
Gain adjustment with test weight
(refer to page 11)
ZF
Fast zero adjustment
(refer to page 13)
GF
Fast gain adjustment with 20% test
weight of Maximum scale capacity
(refer to page 13)
Adjustment (Adj)
switch
0
Operation mode (Run)
Special Functions in “Fast Adjustment, “Setpoint
Adjustment”
LEDs
Annunciator LEDs ( Run, Output type, Error ).
Refer to
Features
Minimized zero and span drifts due to its microcontroller technology and high
accuracy, very low temperature drift, 24 bits ADC and 16 bits DAC converters.
Long time stability and low temperature drifts eliminate the frequent
readjustment period.
Very easy and user friendly digital adjustment via rotary switches located on
the front of the instrument.
Programmable digital adaptive anti-vibration filters to minimize environmental
vibrations.
eCal- electronic calibration without weights and digital filter adjustment via
RS232C port and xFace PC software.
Fast calibration feature to reduce the adjustment time and to minimize
adjustment error.
Calibration at PLC does not require readjustment after changing instrument
because of matching in the production.
2 pcs free relay contact output for alarm or controlling valves, gate etc.