Flint & Walling 50TCPPC Installation Instructions Download Page 2

2

© 2019. All rights reserved.

This product is warranted for one year from the date of purchase or two years 

from the date of manufacture, whichever occurs first.  Subject to the conditions 

hereinafter set forth, the manufacturer will repair or replace to the original 

consumer, any portion of the product which proves defective due to defective 

materials or workmanship. To obtain warranty service, contact the dealer from 

whom the product was purchased. The manufacturer retains the sole right and 

option to determine whether to repair or replace defective equipment, parts or 

components. Damage due to conditions beyond the control of the manufacturer is 

not covered by this warranty.

THIS WARRANTY WILL NOT APPLY: 

(a) To defects or malfunctions resulting from 

failure to properly install, operate or maintain the unit in accordance with printed 

instructions provided; (b) to failures resulting from abuse, accident or negligence or 

use of inappropriate chemicals or additives in the water; (c) to normal maintenance 

services and the parts used in connection with such service; (d) to units which are 

not installed in accordance with normal applicable local codes, ordinances and 

good trade practices; and (e) the unit is used for purposes other than for what it 

was designed and manufactured.

RETURN OF WARRANTED COMPONENTS:

 Any item to be repaired or replaced 

under this warranty must be returned to the manufacturer at Kendallville, Indiana or 

LIMITED WARRANTY

such other place as the manufacturer may designate, freight prepaid.

THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS 

WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. 

ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF 

THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED 

WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER 

SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, 

CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED 

TO DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, 

LOSS OF PROFITS, INCONVENIENCE , OR OTHER INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF 

THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT 

UPON WHICH SUCH LIABILITY  IS BASED.

This warranty gives you specific legal rights, and you may have other rights which 

vary from state to state. Some states do not allow limitations on duration of implied 

warranties or exclusion of incidental or consequential damages, so the above 

limitations may not apply to you.

CONDITION

COMMON

 

CAUSES

A. Pump will not start or run.

Check fuse, low voltage, over load open, open or incorrect wiring, open switch, impeller or seal bound 

mechanically, defective capacitor or relay when used, motor or wiring shorted. 

B. Motor overheats and trips 

overload or blows fuse.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, 

defective capacitor or relay, motor shorted.

C. Pump starts and stops too 

often.

Check valve stuck or none installed in long distance line, over load open.

D. Pump operates but delivers 

little or no water.

Check strainer housing, discharge pipe, or if check valve is used vent hole must be clear. Discharge head 

exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming 

water containing air or causing air to enter pumping chamber.

E. Drop in head and/or 

capacity after a period of use.

Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could 

possibly deteriorate impeller and pump housing. Check line. Remove base and inspect.

If the above checklist does not uncover the problem, consult the factory - Do not attempt to 

service or otherwise disassemble pump.

SERVICE CHECKLIST

ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump 

- making sure you are wearing insulated protective sole shoes and not standing in water. Under flooded conditions, contact 

your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.

IL1879

Item

Part #

Description

1

024602

Base/Top

2

024603

Base/Bottom

Not shown

025280

Capacitor

1

2

In those instances where damages are incurred as a result of an alleged 

pump failure, the Homeowner must retain possession of the pump for 

investigation purposes.

Reviews: