Installation / Operation Manual
anemoi
Calibrate PRS
The
anemoi
pitot
pressure sensor must be calibrated at least once after installation of the device.
Calibration must be done indoors (e. g. hangar). To compensate for any long-term drift of the
differential pressure sensor, a new calibration should be done if the TAS indication exceeds 20 km/h
on ground in calm wind
.
Note that at low airspeed (i. e. on the ground), very small measurement deviations can already cause
significant TAS values, while at flying airspeeds, such errors are diminished. Additionally, airspeed
measurement errors are calibrated in flight by the
anemoi
algorithm. Therefore, indications of < 20
km/h on the ground in calm wind can be ignored. The Calibrate Pressure page is shown in
Figure 6-6: Calibrate Pressure page
Rotate Screen
The screen of the display unit can be rotated in 90 ° steps.
Figure 6-7: Rotate Screen page
Disable AHRS
AHRS indication can be manually disabled (e. g. for competitions). The duration for which the AHRS
will be unavailable can be selected in days, with a maximum of 30 consecutive days. If a duration of
0 days is selected, the system will not be locked. A duration of 1 day means that the system will be
locked for the rest of the present day, and will unlock when booted on the next day, or after (and so
on).