Flextherm GreenCable Mat Series Installation Manual Download Page 7

7

Green Cable 

Mat

TM

 Installation Guide

WARNING:

 PRECAUTIONS TO TAKE WHILE INSTALLING THE 

FLOORING
When mortar is used, never hit the trowel on the heating cable 
to remove excess mortar from the trowel: the cables could 
be damaged. Use a sponge or a wet cloth to remove excess 
cement as you install the tile: do not use a utility knife or the 
edge of your trowel. These tools could damage the heating 
cable. During all operations, lay tools and materials (buckets, 
etc.) on a piece of cardboard instead of directly on the cables.

Note regarding the floor stability

Floor stability will vary according to the type of flooring installed and its 
components. Mortar manufacturers and the Tile Council of North America 
(TCNA) strongly recommend the use of expansion joints on the perimeter 
of the room and obstacles as well as across the room (reference TCNA article 
EJ-171).

Should you require more information regarding tile installation or sub-floor 
construction, contact the TCNA (www.tileusa.com).

Mat verification

Once floor covering installation is complete, verify the mat’s integrity one 
more time, as described in the “Mat Verification” section at the beginning of 
this guide. Record the results on the warranty card.

Connection to the thermostat 

DANGER: SEVERE RISK OF ELECTROCUTION
Turn off the power of the designated electrical circuit prior to 
connecting the system controls.

Compatible thermostats 

Use FLEXTHERM thermostats to operate the system. These thermostats 
are equipped with a class A ground fault circuit interrupter (GFCI) that will 
protect the system in case of fault. To preserve the system’s warranty the use 
of a thermostat equipped with a class A GFCI (5 mA) is required. 

Single-circuit installations

Connect the system’s green wire (ground) to the terminal in the connection 
box. Proceed as per the instructions in the FLEXTHERM electronic thermostat 
installation manual. Identify the circuit on the electrical panel.

Multiple-circuit installations

Should your installation require more than one circuit, you will need one 
thermostat, one master/expansion conversion kit, and the appropriate 
number of expansion units, as indicated in the “Preliminary Electrical 
Installation” section. For their connection, refer to the instruction guide 
provided with the FLEXTHERM thermostat and the FLEXTHERM master/
expansion conversion kit. Identify the circuits on the electrical panel.

Keep installation and user guides 

Please keep the thermostat instructions in a safe place for future reference. 

System start-up

Curing period

Do not turn your system on immediately. The system can be operated 
only after the mortar or self-levelling underlayment has completely cured. 
This waiting period is essential to ensure that the mortar or self-levelling 
underlayment is properly set. Refer to your manufacturer’s instructions to 
verify the curing time for the product you are using (generally 28 days).

Use of rugs

Do not lay a rug on a floor equipped with a heating system. The heat that 
would get trapped could alter your rug or your flooring. The use of a bath 
mat is acceptable, as long as it is removed from the floor once the bath 
period is over. For the same reason, furniture under which air cannot freely 
circulate should not be placed on flooring under which there is a floor 
heating system.

 

Repair

Should the flooring need repair, proceed with caution. Always turn off the 
power supply and remove the piece of flooring that needs to be repaired. In 
the case of ceramic or natural stone floors, gently scrape the grout around 
the tile to be replaced to a maximum depth of 3 mm (1/8 in), and break 
the tile with a hammer starting from the center (do not use excessive force 
which could damage the cable). Without damaging the cable, carefully 
remove the mortar with a chisel or a scraper.

Should the cable be damaged in the process and/or the GFCI be set off, 
the system is out of service and should not be activated. THE CABLE CAN 
BE REPAIRED. A repair kit (product code: FSK-03) is available from your 
FLEXTHERM dealer.

Never attempt to repair a cable located in a wet area. Contact FLEXTHERM 
customer service at 1-800-353-9843.

FLEXTHERM’s Floor Warming and Heating System is maintenance free. 
Should it stop heating, immediately contact FLEXTHERM customer service at 
1-800- 353-9843.

Limited warranty

The Green Cable 

Mat

 bears a 25 year limited warranty. Please 

refer to the FLEXTHERM Warranty Statement inserted in this 
document for complete details.

Return the completed Warranty Registration Card (with the results of the 
three cable verifications - resistance and insulation) in order to preserve the 
Limited Warranty of your system.

Summary of Contents for GreenCable Mat Series

Page 1: ...SPREADTHEWARMTH LA CHALEUR HUMAINE EL CALOR HUMANO INSTALLATION GUIDE GUIDE D INSTALLATION GUÍA DE INSTALACIÓN ...

Page 2: ...the floor heating system will be compromised Only the mesh can be stapled Floor surface preparation General instructions IMPORTANT The sub floor must respect the established construction standards to ensure that it is stable enough to support ceramic tile natural stone or self levelling underlayment Refer to Tile Council of North America publications for installation standards www tileusa com Alwa...

Page 3: ...ion Connect the instrument s black cable to the system ground wire the green lead and the red cable to one of the the heating elements black leads and then send a 1 000 V current picture 3 The result should read infinite ohms Should there be a current leakage between the heating element and the insulation the instrument will indicate a result between 0 500 MΩ Picture 3 Record the results IMPORTANT...

Page 4: ...be spaced at least 13 mm 1 2 in from any exposed combustible surface The heating cable integrated in the mesh mat should at no time be overlapped crossed cut shortened nor modified The spacing between the runs of mat must remain unchanged throughout the installation The entire heating portion of the mat including the mechanical joint must be secured to the floor and covered with mortar or self lev...

Page 5: ...riate locations Apply light pressure to ensure adhesion of the mat to the floor throughout the installation Avoid removing the mat once it has been pressed to the floor If need be stabilise your installation with staples or hot glue At no time should you ever staple the heating cable itself This will jeopardise the functionality of your system Only the mesh should be stapled or glued Wet environme...

Page 6: ...gaps will act as insulating agents and would prevent the heat from reaching the flooring Securing the cold lead to the connection box To make it easier to pass the cold lead through to the connection box wrap the label around the cable picture 8 Picture 8 Tape the label around the cold lead with electrical tape to hold it in place The cable identification label must remain on the cable Removing it...

Page 7: ...on refer to the instruction guide provided with the FLEXTHERM thermostat and the FLEXTHERM master expansion conversion kit Identify the circuits on the electrical panel Keep installation and user guides Please keep the thermostat instructions in a safe place for future reference System start up Curing period Do not turn your system on immediately The system can be operated only after the mortar or...

Page 8: ...colle chaude AVIS En aucun cas le câble chauffant intégré dans la trame ne doit être abîmé percé ou tenu en place à l aide des broches la fonctionnalité de votre système de plancher chauffant en serait compromis Préparation de la surface de plancher Indications générales IMPORTANT Le sous plancher doit respecter les normes de construction établies afin qu il soit assez ferme pour recevoir de la cé...

Page 9: ... ces paramètres contacter le service à la clientèle de FLEXTHERM au 1 800 353 9843 Vérification de l isolation À l aide d un mégohmmètre tester l intégrité de l isolation du câble de la trame Joindre le câble noir de l appareil au fil de mise à la terre fil vert et le câble rouge à un des conducteurs noirs et envoyer une tension de 1 000 V figure 3 Figure 3 Si le câble est intègre l appareil lira ...

Page 10: ...ombustible exposée Le câble chauffant de la trame ne peut être croisé coupé raccourci ou modifié L espacement entre les passes de câbles doit être uniforme en tout temps La trame chauffante incluant le joint mécanique doit être fixée au plancher et recouverte de ciment colle ou de sous finition autolissante En aucun temps la trame chauffante ne peut être installée dans le mur Le système ne doit pa...

Page 11: ...rcer le trou dans le mur à 15 cm 6 po du sol pour éviter la membrane d étanchéité L installation doit respecter les consignes stipulées dans ce guide soit la distance minimale du drain l interdiction de poser une trame chauffante dans les murs etc Pour application valider avec le code électrique local et ou national Installation de la sonde Installer la sonde de lecture du thermostat sur le planch...

Page 12: ...ommande de recouvrir la trame d une couche de ciment colle ou de sous finition autolissante variant entre 6 et 10 mm 1 4 et 3 8 po d épaisseur Acheminement du câble non chauffant à la boîte de raccordement Pour faciliter l aiguillage enrouler l étiquette autour du câble non chauffant Coller l étiquette au moyen de ruban électrique afin qu elle reste enroulée autour du câble figure 8 Figure 8 Laiss...

Page 13: ...ou la sous finition autolissante dans lequel est enfoui la trame Ne pas élever le revêtement de sol au dessus de la masse de ciment l espace d air ainsi créé agirait à titre d isolant et serait un frein à la propagation de la chaleur vers la surface du plancher AVERTISSEMENT MISES EN GARDE À RESPECTER LORS DE LA POSE DU REVÊTEMENT Lorsque le ciment colle est utilisé ne jamais frapper avec la truel...

Page 14: ...NTE El subsuelo o contrapiso debe respetar las normas de construcción en vigor y ser lo suficientemente firme como para recibir la cerámica o la piedra natural Para conocer las normas referirse al Tile Council of North America www tileusa com Para verificar la compatibilidad del subsuelo o contrapiso con este sistema de calefacción referirse al fabricante de los materiales utilizados en la constru...

Page 15: ...XTHERM al 1 800 353 9843 Control de la aislación Con un megóhmetro probar la integridad de la aislación del cable Unir el cable negro del megóhmetro a la puesta de tierra cable verde y el cable rojo del megóhmetro a uno de los conductores negros aplicar una tensión de 1000 V figura 3 Si el cable está entero el megóhmetro indicará un valor infinito En cambio si hay una fuga de corriente entre el el...

Page 16: ...mbustible expuesta El cable calefactor no puede ser cruzado cortado acortado ni modificado No se debe cambiar el espaciado o separación uniforme del cable La malla calefactora incluyendo la junta mecánica debe ser fijada en el subsuelo y recubierta de mortero adhesivo o de alisado o autonivelante En ningún caso la malla calefactora puede ser instalada en un muro La malla no debe ser instalada deba...

Page 17: ...añar el cable calefactor A medida que se va extediendo la malla adherirla al contrapiso mediante una presión leve En la medida de lo posible no despegar la malla una vez que esté adherida Si fuera necesario consolidar la instalación por medio de grapas o de pegamento caliente Tener mucho cuidado de no engrapar directamente el cable calefactor porque esto afectará el funcionamiento del sistema Sólo...

Page 18: ...de sus productos sobre sistemas de calefacción para pisos FLEXTHERM propone dos técnicas de colocación del revestimiento la técnica de recapado con mortero adhesivo y la técnica de recapado con mortero de alisado o autonivelante Estas técnicas son las más comunes Las indicaciones que se dan a continuación no son una guía completa para la instalación de revestimientos sino una serie de indicaciones...

Page 19: ...ucciones de la guía de instalación del termostato FLEXTHERM A continuación identificar el circuito correspondiente en el tablero eléctrico Instalación múltiple Para el caso de una instalación que necesita más de un circuito procurarse un termostato un dispositivo de conversión amo esclavo y un equipo que cuente con la unidades de expansión necesarias como se menciona en la sección Instalación eléc...

Page 20: ...anada Imprimé au Canada Impreso en Canadá FLEXTHERM Inc 2400 de la Province Longueuil Québec J4G 1G1 Canada Tel 1 800 FLEXTHERM 353 9843 450 442 9990 Fax 1 877 FLEXTHERM 353 9843 450 442 1099 client flextherm com www flextherm com ...

Reviews: