![Flexport FX-1600E User Manual Download Page 13](http://html1.mh-extra.com/html/flexport/fx-1600e/fx-1600e_user-manual_2304982013.webp)
The 3
rd
Party Control command
LAN
IP address: 192.168.1.80 (default IP)
Protocol: UDP
Port: 4000
Command: send as hex
Control instruction
Functional description
EB 90 0C 00 00 80 0B 02 (x-1) (y+7) 00 00 Switch [x] input to [y] output
EB 90 0C 00 00 80 09 02 (0X) 00 00 00
Save current scene to [X], [X] means number
keys from 1 to 9
EB 90 0C 00 00 80 08 02 00 (0Y) 00 00
Load the input/output switching saved in [Y], [Y]
means number keys from 1 to 9
For example, input 1 Switch output 6, send: EB 90 0C 00 00 80 0B 02 00 0D 00 00
(1-1)=0, Hex is 00, (6+7) =13, Hex is 0D.
If input 1 Switch output 6, 7, 8, send EB 90 0C 00 00 80 0B 04 00 0D 0E 0F 00 00
04 00 0D 0E 0F means: 04 there are 4 port for switching (1 input and 3 outputs), the first one
00 is the input port, the remaining 0D 0E 0F are the output ports.
EB 90 0C 00 00 80 09 02 02 00 00 00, save the previous scene to the 02;
EB 90 0C 00 00 80 08 02 00 02 00 00, load 02 scene;
EB 90 0C 00 00 80 0B 02 01 0A 00 00
RS232
Baud rate: 9600, N, 8, 1
Use RS232 direct cable
Control instruction
Functional description
[x]X[y].
Switch [x] input to [y] output
Save[X].
Save current scene to [X], [X] means number keys from 1 to 9
Recall[Y].
Load the input/output switching saved in [Y], [Y] means number keys
from 1 to 9
BeepOn.
Turn on the beep sound
BeepOff.