4 Description
4.1 Intended use
The device is designed to change the ventilation mode during use of a cooker hood.
4.2 Working principle
The device communicates with the ventilation unit using wireless communication.
4.2.1 Ventilation speed and mode
During use of a cooker hood the ventilation system is set to
COOKER
HOOD
mode.
•
COOKER
HOOD
mode:
Intended for use together with a cooker hood.
4.2.2 Adjustment of COOKER HOOD mode
The desired fan speeds to be used in
COOKER
HOOD
mode can be set in the Flexit
GO App.
4.3 Visual signals
Startup
Status LED
Power up
Orange Continuous
Status
Status OK
Green
Continuous
Communication error
Red
ȵDVK
Cooker hood mode
ȵDVKHV
&RQȴJXUDWLRQ
Binding
Red/green
5 Operation
When the cooker hood are turned on an automatic change to cooker hood mode on
WKHYHQWLODWLRQXQLWZLOOEHSHUIRUPHG$VVRRQDVWKHWKHFRRNHUKRRGDUHWXUQHGR
the ventilation unit will return the previous mode.
6 Technical data
6.1 Ambient conditions
Operating Temperature Range:
0 to 40 °C
Shipping & Storage Temperature Range:
-20 to 55°C
Relative Humidity:
0 - 90%, non-condensing
ΖQJUHVVSURWHFWLRQΖ(&
IP30
(OHFWULFDOVSHFLȴFDWLRQ
Mains Power Source:
195 - 253 VAC, 50Hz.
Maximum power consumption:
4VA
:LUHOHVVFRQQHFWLRQVSHFLȴFDWLRQV
Communication frequency:
868.3 MHz
Output power:
at least 0 dBm
You are not allowed to use the
device outside of Europe.
6.4 Pressure adjustment range
Adjutment range:
40 to 300 Pa
Our products are subject to continuous development and we therefore reserve the right
to make changes. We also disclaim liability for any printing errors that may occur.