7 Connection
7.3 Outputs
FLUXUS F808
2020-06-25, UMFLUXUS_F808V2-2EN
74
7.3
Outputs
• Connect the output cable to the transmitter.
For the connection of the output cable to the transmitter, see section 7.2.1, Fig. 7.21 and Tab. 7.18.
Fig. 7.20: Cable gland
1 – cap nut
2 – compression part
3 – basic part
Important!
The max. permissible voltage between the outputs and against PE is 60 V DC (permanent).
Fig. 7.21: Connection of the outputs on the transmitter
1 – connection of the outputs
Tab. 7.18: Circuit of the outputs
output
transmitter
external circuit
remark
internal circuit
connection
active current output
R
ext
< 500 Ω
passive current output
U
ext
= 4…24 V
U
ext
> 0.021 A
.
R
ext
[Ω] + 4 V
example:
U
ext
= 12 V
R
ext
≤ 380 Ω
The number, type and the connections of the outputs depend on the order.
R
ext
is the sum of all ohmic resistances in the circuit (e.g., resistance of the conductors, resistance of the amperemeter/voltmeter).
2
1
3
ARS
AR
AV
AVS
L(+)
N(-)
PE
KL4
KL1
KL2
KL3
1
1
+
-
I1: 2 (+)
I1: 1 (-)
KL3
mA
-
+
I1: 1 (-)
I1: 2 (+)
KL3
mA
U
ext
+
-