FlexDSL Telecommunications AG
Steinackerstrassse 31
8902 Urdorf
Switzerland
Page 6/6
Tel: +41 44 741 52 90
Fax: +41 44 741 52 93
Email: [email protected]
Web: www.flexdsl.ch
Environment , EMC and Safety
Storage:
ETS 300 019-1-1 Class 1.2 (-25
°
C … +55
°
C)
Transportation:
ETS 300 019-1-2 Class 2.3 (-40
°
C … +70
°
C)
Operation:
ETS 300 019-1-3 Class 3.2 (-25
°
C … +70
°
C)
ETS 300 019-1-3 Class 3.4 When inside an outdoor rack
Higher Operation Temperature range available on request (-25°C … +80°C)
Dimension SHDSL & Single FOM:
143(W)x87(D)x37(H) mm, 153(W)x87(D)x37(H) mm with Clip
Dimension Dual FOM:
143(W)x87(D)x43(H) mm, 153(W)x87(D)x43(H) mm with Clip
Weight
< 0.5kg in Metal DIN-Rail Enclosure
Standards:
EN 300386 V1.4.1:2008
EN 55024/A2:2003
EN 61000-4-5:2006
EN 50121-4:2006
EN 61000-4-2/A2:2001
EN 61000-4-6:2007
EN 60950-1:2006
EN 61000-4-3:2006
EN 61000-4-6/A1:2001
EN 55022:2006, Class B
EN 61000-4-4:2004
Available Models
Ordering Code
Interfaces
Power Supply
Attention!
MF-PAM-RAIL2N-2Eth-24V, V1
2xDSL 2xETH
18-72VDC
MF-PAM-RAIL2N-2Eth-230V, V1
2xDSL 2xETH
110/230VAC
MF-FOM-RAILN-Eth-24V, V1
1xFOM (SFP Cage) 1xETH
18-72VDC
MF-FOM-RAILN-Eth-230V, V1
1xFOM (SFP Cage) 1xETH
110/230VAC
MF-FOM-RAIL2N-2Eth-24V, V1
2xFOM (SFP Cage) 2xETH
18-72VDC
MF-FOM-RAIL2N-2Eth-230V, V1
2xFOM (SFP Cage) 2xETH
110/230VAC