Installation, Operation, & Maintainance Guide
Style 60/62/65
LAYOUT
•
If the seal is being installed on equipment without a preset step, snap ring groove, etc. use
the procedure described below to mark the reference distance (using values found on Page
), otherwise this section can be used to verify the distance of the existing geometry. Ensure
that the seal’s shaft packing is not mounted on any part of a step or groove prior to final
installation.
Style 60/62/65 high temperature bellows rotaries are exclusively intended for
inside-mounted
use. Do not mount outside of the seal chamber.
1
.
Do not scratch the shaft or sleeve when scribing during the layout procedure.
Figure 8: Fully assembled pump without seal
#1
Figure 9: Layout dye application and scribe
#2 #1
GLAND
GLAND GASKET
L
MATING RING
Figure 10: Measure seal face location
#2 #1
Figure 11: Scribe location of seal face
#2 #1
#3
C
Figure 12: Setting length scribe
#2 #1
#3
.050 REF.
Figure 13: Assembled seal chamber
Page 4 of 9