22
Ignition Setup
(Figure 17)
Field
Action
Default
Record
Control
Enables or disables immediate
recording at unit startup. When
enabled the Record Start and
Stop delays are activated.
Enable
Record Start
Delay
Delay time before record start
following ignition ON.
0Min
Record Stop
Delay
Delay time before record stop
following ignition OFF.
0 Min
Power Off
Delay
Delay time after ignition OFF and
Recording stopped with no
activity before unit power off.
Note: setting this field to minus 1
(‘-1’) keeps unit on indefinitely
until power removed. Caution:
This can run a battery down.
10 Min
The ignition trigger has special handling inside the MDVR intended to
support motor vehicle applications where recording can start and stop
automatically. Enabling the Record Control field in the Ignition Setup
turns ON the automatic recording features. The following table details
how specific events are handled.
Record
Control
Setting
Ignition
State of
Manual
Power
button
System Behavior
DISABLE
ON
Turning ON
Turn ON
DISABLE
OFF
Turning ON
Turn ON, but turn OFF automatically after
idle for Power OFF Delay
DISABLE
OFF
Turning OFF
Turn OFF immediately (under manual
control)
DISABLE
Turning OFF
ON
Turn OFF after Power OFF Delay
DISABLE
ON
Turning OFF
Turn OFF immediately (under manual
control)
DISABLE
ON
ON
Turn OFF after Power OFF Delay
DISABLE
Turning ON
OFF
Turn ON (for completely manual operation,
disconnect ignition trigger)