Flavor Burst CW 194 Instructions Download Page 2

A    ADJUSTING ALTERNATING INGREDIENT TIMING 

Press the Cancel Entry key to set the adjustment and 
exit the mode. 

Draw a serving to determine if the adjustment is 
satisfactory. Repeat this process until the correct 
ingredient concentration is achieved. 

To increase the timing (for wider layers), press the 
LARGE CUP (+) key until the correct number of bar 
graph lights are lit. 

To decrease the timing (for more narrow layers), press 
the SMALL CUP (-) key until the correct number of bar 
graph lights are lit. 

Press and hold the #1 and #2 keys simultaneously until 
the keypad lights flash. 

The number of lighted bars in the graph represent the 
length of time each layer is dispensed.  Use the 
following chart to determine the bar graph setting 
needed for the desired dispense time for each 
ingredient layer. 

CW 194 KEYPAD OVERLAY - AUTO- continued 

REV031008

pg. 2 of 3 

NOTE:

 IF THIS IS THE FIRST TIME 

ALTERNATING INGREDIENT TIMING HAS BEEN 

SET, SET THE TIMING TO ONE LIGHT (.5 SECONDS), 
DRAW A SERVING, AND THEN ADJUST THE TIMING FOR 
WIDER LAYERS IF NEEDED. 

ALT. INGREDIENT TIMING 

1 Light       = 

.5 seconds 

2 Lights      = 

.6 seconds 

3 Lights      = 

.7 seconds 

4 Lights      = 

.8 seconds 

5 Lights      = 

1.0 seconds 

6 Lights      = 

1.2 seconds 

7 Lights      = 

1.4 seconds 

8 Lights      = 

1.6 seconds 

9 Lights      = 

1.8 seconds 

10 Lights

    

= 2.0 

seconds 

Reviews: