Page 1: ...COAL EFFECT GAS FIRE User Instructions Hand these instructions to the user Model No s FIRC MN FIRC MN are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E denotes trim fret...

Page 2: ...e made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the Nat...

Page 3: ...this appliance is serviced at least once a year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for...

Page 4: ...at up if the pilot goes out when the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and...

Page 5: ...as been allowed to fully cool CLEANING THE BRASS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen to clean the trim...

Page 6: ...not lodged on the burner See fig 1 below Fig 1 b Place the left hand front coal rail moulding onto the front ceramic rail support as shown below in Fig 2 Fig 2 6 NOTE The position of the fuel bed com...

Page 7: ...c Place the right hand front coal rail moulding onto the front ceramic rail support as shown below in Fig 3 Fig 3 d Fit four large coals behind the ceramic front rails as shown below in Fig 4 Fig 4 7...

Page 8: ...small coals and fit onto the ribs of the fuel bed base See fig 5 below Fig 5 f Select the remaining four small coals and arrange along the rear of the fuelbed directly behind the third row of coals Se...

Page 9: ...ls If any coals are missing please contact your retailer Do not proceed with the installation Fig 7 h Ensure the flame paths are un interrupted as shown below in Fig 8 If necessary make minor adjustme...

Page 10: ...posed of at a landfill licensed to accept such waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drin...

Page 11: ......

Page 12: ...t the exact accuracy of descriptions and illustrations cannot be guarantee Part no B 103820 Issue 2 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone Gene...