
MAINTENANCE INSTRUCTIONS
Servicing Notes
Servicing should be carried out annually by a competent person such as a
Corgi registered engineer.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for positive up-draught in
the chimney.
The condition of the ceramic plaques should be checked and if necessary the
whole set should be replaced with a genuine replacement set.
After any servicing work a gas tightness check must always be carried out.
4.1
GENERAL ACCESS FOR SERVICING
4.1.1
TO REMOVE THE UPPER CANOPY
a)
Prepare work area (lay down dustsheets etc.), Disconnect the appliance
from the gas supply.
b)
Remove the four canopy rear fixing screws, and the two fixing screws
that are located on the underside of the canopy (see fig 5 & 6
respec tively)
c)
Remove the radiants and move to a safe place
d)
Re-assemble in the reverse order.
Fig. 5
Removing the four canopy rear fixing screws
15
Fixing Screws
Summary of Contents for Regent FRGCN0MN
Page 27: ......