Flavel Pure FPRG**RN2 User Instructions Download Page 8

The ceramic fibre back & imitation gravel used in this product is

manufactured from R.C.F (Refractory Ceramic Fibre). To ensure that the

release of fibres from this item is kept to a minimum, during installation and

servicing we recommend that you use a HEPA filtered vacuum to remove

any dust accumulated in and around the appliance before and after working

on the appliance. When replacing these articles we recommend that the

replaced items are not broken up, but are sealed within heavy duty poly-

thene bags, clearly labelled as “RCF waste”. RCF waste is classed as a “sta-

ble”, non reactive hazardous waste and may be disposed of at a landfill

licensed to accept such waste Protective clothing is not required when

handling these articles, but we recommend you follow the normal hygiene

rules of not smoking, eating or drinking in the work area, and always wash

your hands before eating or drinking.

CLEANING - WARNING

Before attempting any cleaning operation ensure that the fire has been allowed to

fully cool.

CLEANING THE STAINLESS STEEL AND PAINTED METAL PARTS

The “Pure” fascia that was supplied with this product must only be cleaned with a

clean, damp cloth.

Abrasive cleaners, chemical cleaning agents or any type of polish must

never be used as damage to the finish may result.

CLEANING THE CERAMIC FUEL-BED COMPONENTS

We do not recommend cleaning of the ceramic fuel-bed fibre base or imitation

ceramic gravel as these items are fragile and damage may result.

None of these parts must be washed or exposed to any cleaning agents or

water

.

Any damaged parts must be replaced by contacting your dealer or telephoning

BFM Europe Ltd. on the number stated on the rear cover of this book. The

ceramic fibre base must only be replaced with a complete and genuine item and

the fire must never be run with a damaged item in position.

8

Summary of Contents for Pure FPRG**RN2

Page 1: ...Pure DECORATIVE FUEL EFFECT GAS FIRE User Instructions Model No s FPRG RN2 is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E NB refers to fascia variant...

Page 2: ...ditional overhang in excess of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domest...

Page 3: ...emoved from the fire opening and the flue pipe chimney visually checked for debris or blockages which must be removed During the annual service replacement of the Oxypilot and ribbed fuel bed base pan...

Page 4: ...ent of repeated operation a CORGI registered gas installer must be called to investigate and rectify the cause CHANGING THE BATTERIES REMOTE HANDSET The battery in the remote handset can be changed by...

Page 5: ...isc set in the MAN position d Switch the main valve knob to the OFF position Image above shows MAIN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand...

Page 6: ...flame will remain lit If you wish to turn off the fire altogether press the STAR OFF button AFTER THE PILOT FLAME HAS BEEN EXTINGUISHED IF YOU WISH TO RE LIGHT THE APPLIANCE YOU MUST WAIT AT LEAST TH...

Page 7: ...in Fig 3 below then securing with magnets at the bottom Fig 3 CERAMIC FUEL BED GRAVEL a The gravel pieces should be randomly placed onto the grooved base of the product as shown below in Fig 4 The gra...

Page 8: ...r drinking in the work area and always wash your hands before eating or drinking CLEANING WARNING Before attempting any cleaning operation ensure that the fire has been allowed to fully cool CLEANING...

Page 9: ...ard Beige Fibre B 97420 Fuel bed gravel set Grey Cream 100 off approx pieces B 97530 Fuel bed gravel set Cream 100 off approx pieces B 99250 Due to our policy of continual improvement and development...

Reviews: