Supplied By www.heating spares.co Tel. 0161 620 6677
TROUBLESHOOTING
Fire Illuminates but no flame effect
Check the flame effect disc is free
is seen
from obstruction (behind coal effect)
Fire operates with heat then cuts out
Safety ‘Cut-Out’ has operated,
ensure the heater is not covered or
obstructed. Turn off appliance and
wait 10 mins to reset. Retry
appliance.
No flame effect is seen after switch is
Check condition of bulb (see below)
switched to position I
If bulb is ok check condition of fuse.
It is important that any electrical work is undertaken by a suitably
qualified, competent person.
CHANGING THE LIGHTBULB
Disconnect from mains supply.
Remove brass trim (three parts)
Remove coalform retaining brackets (LH / RH) secured with two screws.
Remove one of two screws retaining flame effect disc and rotate away from bulb.
Remove bulb from bulbholder, and refit new 60W firelglow bulb.
Refit the flame effect disc / holder (two screws).
Refit coalform and retaining brackets (ensure flame effect disc is freely rotating)
Refit brass trim.
The Following Spare Parts are available from the manufacturer (details on
back page)
B-53310
Coal Effect Front
B-59870
60W Fireglo Bulb
B-61020
LH Trim
B-61030
RH Trim
B-61040
Top Trim