![Flavel Emberglow Classic RC User Manual Download Page 23](http://html1.mh-extra.com/html/flavel/emberglow-classic-rc/emberglow-classic-rc_user-manual_2303336023.webp)
4.5
REMOVING THE CONTROL BOARD
a)
Disconnect the appliance from the gas supply.
b)
Remove the glass front panel as descibed on page 9, (fig. 2)
c)
Remove the coals and fuel-bed matrix. Pull the fire forwards and tilt fire
onto its back to allow access to control board underneath (situated in
centre).
d)
Disconnect the wiring looms
e)
Replace in reverse order, re-connect to gas supply and carry out a gas
tightness test
PARTS SHORTLIST
Replacement of any parts must be carried out by a competent person such as a
CORGI registered gas installer. The part numbers of the replaceable parts are as
follows, these are available from specialist spares stockists whose details can be
found on our web site, www.bfm-europe.com, in the ‘stockist’ section.
Coal set
FC-P085332 ODS Pilot (NG)
B-49710
Fuelbed
B-123570
EDB Control Board
B-106800
Gas valve (NG)
B-106790
Battery Holder
B-106820
Rear Fibre board
B-65320
Remote Handset
B-63600
Glass Assy (Front)
SFA-085165
23
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.