![Flavel Arundel XL MK2 Installation And Operating Instructions Manual Download Page 4](http://html.mh-extra.com/html/flavel/arundel-xl-mk2/arundel-xl-mk2_installation-and-operating-instructions-manual_2303392004.webp)
Section 1 - Stove Information
1.1
This Flavel Arundel XL MK2 multi-fuel stove meets the safety and performance
requirements of European Standard EN 13240 for intermittant burning solid fuel
roomheaters for installation in a dedicated chimney when operated in accordance
with these instructions. Independently tested by KIWA UK.
1.2
Stove Dimensions - see figure 1 below.
The stove is supplied with the following loose items :-
1 off ashpan, 1 off ashpan handle tool & 1 off stove glove.
Section 2 - Stove Performance Data
Page 4 of 20
Fig. 1
Fuel
Wood (Beech)
Mineral Fuel (Maxibrite)
Test standard
EN 13240 : 2001 + A2 2004
EN 13240 : 2001 + A2 2004
Re-fuelling Interval
0.8hrs
1.0hrs
Settings
0% primary, 50% secondary
50% primary, 0% secondary
Flue draught (Pa) (ins WG)
12 (0.05)
12 (0.05)
Efficiency
82.2%
83.6%
Recommended output (kW)
5.0
5.0
Mean flue gas temperature (
o
C)
224
250
Minimum air entry requirement
2700mm
2
2700mm
2
Minimum clearance to
combustible surfaces
750mm Rear, 600mm Side,
1000mm Front.
750mm Rear, 600mm Side,
1000mm Front.
Emissions if O2 = 13%
CO %
0.09
0.07
Flue gas mass flow (g/s)
4.4
2.9
Mean CnHm (Nmg/m3)
76
14
Mean NOx (Nmg/m3)
97
88
DIN Plus Dust (Nmg/m3)
18
21