Flashforge 6937120300397 User Manual Download Page 16

Q:
A:

Q:
A:

Q:
A:

Is it very power-consuming to keep the filament drying station on for a long time?

The power consumption will be high only in the drying mode, while there is almost 
no power consumption in the storage mode.

What happens when the desiccant is in the regenerative cycle mode?
At this time, the equipment is dehumidifying the desiccant to achieve the purpose of 
reuse. At this time, the humidity data may rise.

Is there a door sensor function?
There is a door sensor function. If the door open detection function is turned on, the 
drying and automatic storage (drying) functions will be enabled only when the door 

is closed tightly. It is also feasible to turn off the door detection function and then 

there will be no further detection of whether the door is closed or not.

Q:
A:

How does the door detection sensor affect the functions of the equipment?

If the door detection is not triggered (the door is not closed properly), the equipment 
will not give any prompt, and will not carry out the storage mode or the drying mode. 
It is necessary to ensure whether the door is closed properly.

When the door detection function is turned off in the settings, the drying and storage 

functions will be enabled whether the door is closed properly or not.

Q:
A:

How long is the estimated time for the indoor humidity to drop from 50% to 10%?
It will take about half an hour to reduce the indoor humidity from 50% to 10%.

Q:
A:

What is the power consumption of the filament drying station drying for 12 hours?
When at room temperature, the target drying temperature is set at 120℃, the power 

consumption is about 1.4KWh.

14

Summary of Contents for 6937120300397

Page 1: ...This guide is only applicable to FLASHFORGE Filament Drying Station P16 USER GUIDE EN CN A01 Filament Drying Station...

Page 2: ...1 3 Equipment Parameter 1 4 Combined Use 2 Equipment Operation Introduction 2 1 Storage Function 2 2 Drying Function 2 3 Annealing Treatment 2 4 Filament Drying Station Setting 3 Replace the Desiccan...

Page 3: ...damp or hot sun environment Humidity will increase the risk of electric leakage Exposure to sunlight will accelerate the aging of plastic parts Make sure to only use the power cord provided by Flashfo...

Page 4: ...ne is allowed to modify or translate this guide without the permission of Flashforge This guide is protected by copyright and Flashforge reserves the right of the nal interpretation of this guide Flas...

Page 5: ...ip Stop Block Display Screen Caster Protective Cover Drawer Slide Rear Cover Plate Power Switch Power Outlet Back Plate Air Inlet Air Outlet 1 2 3 4 5 6 7 8 9 1 1 Product Introduction 1 2 Packing List...

Page 6: ...ial 840x 675y 600z mm with casters 4 3 inch touch screen Chinese English Japanese German French Korean 120 1 year 800g 10 20 500 375 200 mm WxDxH 500W 120kg 980 780 830 mm 100kg Average 30W Maximum 35...

Page 7: ...drying station can be used together with Creator 4 series equipment which can be placed above the lament drying station After nishing placing tighten the installation xing block with screws 1 4 Combi...

Page 8: ...midity of the lament chamber The humidity value will change as the storage function is turned on until the humidity reaches the set humidity storage range It adopts the renewable desiccant which can b...

Page 9: ...d during drying If the hot melt characteristics of the materials di er greatly they can not be dried at the same time For example PLA material of which the softening temperature is 53 is not suitable...

Page 10: ...re varies under di erent experimental conditions 08 PA12 CF15 9891BK PA6 CF10 PA66 CF10 PET CF15 9780BK PETG CF10 PLA CF10 PC ABS PA6 66 PA1010 PAHT PC PP HIPS PLA PRO PLA PETG PRO PETG ABS PRO PBT 90...

Page 11: ...nd PA12 CF should be annealed to improve the mechanical properties of the model samples Annealing conditions PA Place the sample in the Filament Drying Station at 70 and dry it for 2 hours PAHT Place...

Page 12: ...will not be started even when the desiccant in the chamber has become moisture satu rated Therefore the storage function will fail as the desiccant becomes invalid Recommended humidity for material s...

Page 13: ...door open detection function is turned on when the equipment door is opened the drying function and storage function will not be enabled in order to prevent shortening the service life of desiccant If...

Page 14: ...ing ring and the heat insulation foam Loosen the four screws shown in the figure with an Allen wrench Turn over the aluminum substrate assembly in the direction of the arrow and take out the desiccant...

Page 15: ...haracteristics are similar such as PA12 CF and PA6 CF they can be dried at the same temperature for 8 to 12 hours If the temperature resistance characteristics of materials are far di erent they can n...

Page 16: ...then there will be no further detection of whether the door is closed or not Q A How does the door detection sensor a ect the functions of the equipment If the door detection is not triggered the doo...

Page 17: ...s are answered there http www ashforge com The Flashforge support team can be reached by e mail or phone between the working hours of 8 00 a m to 5 00 p m PST Monday through Saturday In case you conta...

Page 18: ...1 1 1 2 1 3 1 4 2 1 2 2 2 3 2 4 Q A 17 19 19 19 20 21 22 22 22 24 25 27 28 29 16...

Page 19: ...15 30 20 70 10cm 17...

Page 20: ...2022 3 Copyright 2022 18...

Page 21: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 1 1 1 2 19 10 11 12 14 13 15 2 4...

Page 22: ...g 10 20 500 375 200 mm 500W 120kg 980 780 830 mm 100kg 30W 35W 100W 500W 1 4KWh PVA PVOH BVOH PVB PA6 PA12 PA66 PC ABS ABS Pro HIPS ASA PET PETG WOOD Metal Fill PA6 CF PA12 CF PA66 CF PET CF PP CF ASA...

Page 23: ...4 4 1 4 21...

Page 24: ...15 2 1 2 2 22...

Page 25: ...2 5 PC ABS 50 PA12 CF15 9891BK PA6 CF10 PA66 CF10 PET CF15 9780BK PETG CF10 PLA CF10 PC ABS PA6 66 PA1010 PAHT 90 200 150 100 70 60 123 85 100 90 PC PP HIPS PLA PRO PLA PETG PRO PETG ABS PRO PBT 105 1...

Page 26: ...2 3 PA PAHT PA12 CF PA 70 2 PAHT 70 2 PA12 CF 80 6 PA PAHT PA12 CF Mpa 80 70 60 50 40 30 20 10 0 PA PAHT PA12 CF 46 55 63 79 53 71 24...

Page 27: ...2 4 10 15 20 25 PVA PA TPU PLA ABS PETG PC PBT 25...

Page 28: ...7 26...

Page 29: ...4 4 27...

Page 30: ...Q A Q A Q A Q A 1 0 3 Q A PA12 CF PA6 CF 8 12 PLA PC PLA 55 PLA Q A Q A Q A Q A Q A Q A 12 120 1 4KWh Q A 50 10 50 10 Q A 28...

Page 31: ...QQ www sz3dp com 8 00 5 00 QQ 400 8866023 QQ 2850862986 2850863000 2853382161 3D QQ 206773820 518 S N FFAD 29...

Page 32: ...Zhejiang Flashforge 3D Technology Co Ltd Address No 518 XianYuan Road Jinhua City Zhejiang Province China Service Hotline 86 579 82273989 support ashforge com Follow us...