2.2 Wiring the Beacon
The beacon is supplied with a 50-foot length of power & alarm cable pre-wired to the internal
electronics to facilitate installation (see Table 2-1). The only connections required are power
(120-240 VAC, 50/60 Hz) and ground. The ground wire must be connected for proper operation
and protection of the beacon.
Optional dry contact monitoring connections permit monitoring of beacon operation.
The
contact is closed when the beacon is operating normally and no fault is detected.
The Auxiliary Control Input allows an external device, such as a radar system, to inhibit the
flashing of the beacon (see Table 2-2). The acceptable input voltage range for the Control Input
is 5 – 30 Volts AC/DC. The optional 10 conductor cable is required to utilize this feature.
Table 2-1 – Standard Power & Alarm Connections
5
C
o
n
d
u
ct
o
r
C
a
b
le
Wire
Color
Function
FTB 370i-2 Beacon
Internal Connections
External
Connections
Black
Input Power
TB1 - L1
(120 VAC) - Line
(240 VAC) - L1
White
Input Power
TB1 - L2
(120 VAC) - Neutral
(240 VAC) – L2
Green
Ground
TB1 - GND
Ground
Red
Alarm Contact
TB1 - COM
Alarm Input
1
Orange
Alarm Contact
TB1- NC
Alarm Input
1
Table 2-2 – Power, Alarm & Radar Interface Connections
1
0
C
o
n
d
u
ct
o
r
C
a
b
le
(O
p
tio
n
a
l)
Wire
Color
Function
FTB 370i-2 Beacon
Internal Connections
External
Connections
Black
Input Power
TB1 - L1
(120 VAC) - Line
(240 VAC) - L1
White
Input Power
TB1 - L2
(120 VAC) - Neutral
(240 VAC) – L2
Green
Ground
TB1 - GND
Ground
Red
Alarm Contact
TB1 - COM
Alarm Input
1
Orange
Alarm Contact
TB1- NC
Alarm Input
1
Brown
Auxiliary Control Input
TB1 – AUX -
Control Output
2
Blue
Auxiliary Control Input
TB1 - AUX +
Control Output
2
Violet
Ground
Chassis GND
Ground
Yellow
Ground
Chassis GND
Ground
Gray
Ground
Chassis GND
Ground
Drain
Ground
Chassis GND
Ground
1. Refer to the monitoring system manufacturer’s installation manual for connection locations.
2. Refer to the radar system manufacturer’s installation manual for connection locations.
Summary of Contents for VANGUARD FTS 370i-2
Page 2: ...ii Revision A 05 17 2019 FTS 370i 2 IR This page intentionally left blank...
Page 19: ...FTS 370i 2 IR Revision A 05 17 2019 13 Figure 4 1 Beacon Wiring Diagram Standard...
Page 20: ...14 Revision A 05 17 2019 FTS 370i 2 IR Figure 4 2 Beacon Wiring Diagram 10 Conductor Option...
Page 26: ...20 Revision A 05 17 2019 FTS 370i 2 IR Figure 5 2 Base Component Locations...