FTS 370d/w/r
Revision 10 – 1/09/2015
103
Marker Settings and Diagnostics
Register
Address
Read/Write
Register Name
Description / Values
240
R/W
Marker Tier Select Register
1-6, indicates/selects which system Marker Tier data is
reflected below
242 – 272
R
Marker Board Firmware
Revision String
ASCII string, null terminated
273 – 288
R
Marker Board Universally
Unique Identifier
Binary data identifier
289
R
Marker Output 1 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 1
290
R
Marker Output 2 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 2
291
R
Marker Output 3 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 3
292
R
Marker Output 4 Current Draw
A2D
An A2D value representing the current draw of Marker
Output 4
293
R
Marker Drive Voltage A2D
An A2D value representing the voltage that is driving all
the Marker Outputs
294
R
Marker Input Power Voltage
A2D
An A2D value representing the Input Power Voltage Level
295
R
Marker Internal Temperature
A2D
An A2D value representing the Marker Box Internal
Temperature
296
R
Individual Marker Status
If a marker alarm is detected in Tower Monitoring (register
82), the specific marker that failed can be determined
here:
Bit 0 – A ‘1’ indicates that Marker 1 is in alarm
Bit 1 – A ‘1’ indicates that Marker 2 is in alarm
Bit 2 – A ‘1’ indicates that Marker 3 is in alarm
Bit 3 – A ‘1’ indicates that Marker 4 is in alarm
Summary of Contents for VANGUARD FTS 370d
Page 2: ......
Page 36: ...24 Revision 10 1 09 2015 FTS 370d w r Figure 2 5 Marker Interface Wiring ...
Page 54: ...42 Revision 10 1 09 2015 FTS 370d w r Figure 2 21 Typical Catenary System Wiring Diagram ...
Page 94: ...This page intentionally left blank ...
Page 96: ...84 Revision 10 1 09 2015 FTS 370d w r Figure 6 1 SC 370 AC Component Locations ...